Symbols used
Symbol indicates a possible hazard.
Note containing information and tips.
Intended use
The Truma Combi CP plus ready liquid gas heater is a warm-
air heater with integrated hot water boiler (10 litre capacity).
This unit was designed for installation in motor homes and
caravans. The equipment must not be installed in buses or
vehicles for transporting hazardous goods (vehicle class M2
or M3).
Other applications are permitted after prior consultation with
Truma.
Function description (Combi)
The Truma Combi liquid gas heater is a warm-air heater with
integrated hot water boiler (10 litre capacity). The burner is
fan-assisted, which ensures that operation is problem-free,
even when on the move.
In heating and hot water mode the heater can be used to
heat the room and heat water up at the same time. If only hot
water is required, select hot water mode.
In hot water mode, the water contents are heated at the
lowest burner setting. Once the water temperature has
been reached, the burner switches off.
In heating and hot water mode, the unit automatically
selects the required operating level according to the tem-
perature difference between the temperature set on the
control panel and the current room temperature. If the boil-
er has been filled, the water is automatically heated as well.
The water temperature depends on the selected operating
mode and the heater output.
At a temperature of approximately 3 °C at the automatic
FrostControl safety/drain valve, the valve will open and drain
the boiler.
Function description (Combi E)
The Combi E liquid gas heater is a warm-air heater with inte-
grated hot water boiler (10 litre capacity). The burner is fan-
assisted, which ensures that operation is problem-free, even
when on the move. The unit also has heating elements for
electrical operation.
In heating and hot water mode the heater can be used to
heat the room and heat water up at the same time. If only hot
water is required, select hot water mode.
At a temperature of approximately 3 °C at the automatic
FrostControl safety/drain valve, the valve will open and drain
the boiler.
3 different options are available for operating the unit:
gas mode only
Propane / Butane for autonomous use
electrical mode only
230 V for stationary use on camp sites
or gas and electrical mode – mixed mode
Only possible in winter.
Heating and hot water mode
In heating and hot water mode, the unit automatically
selects the required operating level according to the tempera-
ture difference between the temperature set on the control
panel and the current room temperature. If the boiler has
been filled, the water is automatically heated as well. The wa-
ter temperature depends on the selected operating mode and
the heater output.
All 3 energy selection options can be used for winter
deployment.
In gas mode the unit automatically selects the operating
level that is required.
In electrical mode output of 900 W (3.9 A) or 1800 W
(7.8 A) can be manually preselected in accordance with the
fuse protection at the camp site.
If more output is required (e.g. heating up or low outside
temperatures) gas or mixed mode should be selected so
that enough heating power is always available.
In mixed mode 230 V electrical mode is preferred if the
power requirement is low (e.g. for maintaining the room
temperature). The gas burner is not enabled until the power
requirement is higher, and is the first to switch off during
heat-up operations.
Hot water mode
(with filled boiler only)
Gas mode or 230 V electrical mode is used to generate hot
water. The water temperature can be set to 40 °C or 60 °C.
In gas mode the water is heated at the lowest burner
setting. Once the water temperature has been reached,
theburner switches off.
In electrical mode output of 900 W (3.9 A) or 1800 W
(7.8 A) can be manually selected in accordance with the
fuse protection at the camp site.
Mixed mode is not possible. With this setting the unit
automatically selects electrical mode. The gas burner is
not enabled.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Combi E CP plus ready wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info