Safety instructions
Repairs may only be carried out by an expert!
To avoid transportation damage, the device may only be
dispatched if the Truma Service Centre in Germany or the
respective authorised service partner has been consulted
beforehand.
The power supply must be disconnected from the mains (all
poles) before opening the housing.
The 230 V, T 6.3 A H-type (slow, IEC 127) device fuse can be
found on the electronic control unit in the device, and must
always be replaced with an identical fuse.
The device fuses and connection cables must only be re-
placed by experts.
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
Modifications to the device (including accessories)
Failure to use original Truma parts as replacement parts and
accessories
Failure to follow the installation and operating instructions
This may also invalidate the device operating permit, which in
many countries also denotes cancellation of the vehicle oper-
ating permit.
The refrigerant circuit contains R 407C refrigerant and must
only be opened in the factory.
The air outlet and and the circulated air intake must not be
obstructed under any circumstances. This is essential in order
to ensure that your device operates correctly.
The openings beneath the floor of the vehicle must be kept
free of dirt and slush. These openings must not be within the
range of the wheel spray – fit splash guard if necessary.
If underbody protection is being applied to the floor of the
vehicle, all openings beneath the vehicle must be covered so
that the spray mist that is created does not penetrate the de-
vice and cause malfunctions. Remove covers again when the
work is complete.
In order to avoid damage to the compressor, no uphill or
downhill slopes with an incline of more than 8 % must be
driven on when the device is being operated while driving
(e.g. with generator or voltage converter).
Do not operate the device for long periods with the vehicle at
an angle, since the condensation that is produced may not be
able to run away and may penetrate the vehicle under unfa-
vourable circumstances.
In order to ensure that the equipment works properly and to
avoid damage, only power supply sources with a purely sinu-
soidal waveform (e.g. voltage converter, generator) and with-
out voltage peaks must be used.
When the floor of the vehicle is being cleaned, it must be
ensured that no water penetrates the openings in the base
of the device when spraying with a high-pressure cleaner, for
example.
For safety reasons the device must always be closed during
operation, since this is the only way to ensure that no injuries
are caused by moving parts. Then strap around the electronic
housing must not be removed.
Notes on using air conditioning systems
The Saphir comfort RC air conditioning system is designed for
minimal power consumption. You should still check whether
the camp site has adequate fuse protection (min. 6 A) before
starting the equipment up.
Park the vehicle in the shade if possible.
Darkening with shutters and / or a canopy reduces the
amount of heat radiation.
Clean your roof at regular intervals (dirty roofs heat up more
than clean roofs).
The vehicle must be properly ventilated before starting the
equipment in order to remove accumulated warm air from
the vehicle.
When aprons or the like are being fitted, please ensure that
adequate openings are present for dissipating the supply
air. The opening for the warm outgoing air should not be at
the inlet side.
In order to obtain a healthy room climate, the difference
between the inside and outside temperatures should not be
too great. The recirculated air is cleaned and dried during
operation. A pleasant room climate is produced by drying
the moist air, even if the temperature difference is minimal.
Keep all doors and windows closed when in cooling mode.
Full ventilation power can only be achieved at all three
openings if three cold air ducts are connected.
The blow-out duct (part no. 40040-32500) must not be used.
When in heating mode, only use “high” fan level for rapid
heating. Set to “medium” or “low” during continuous
operation.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Saphir comfort RC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info