Before starting to use the device, it is essential that the
Operating Instructions and “Safety instructions” be read
carefully. The vehicle owner is responsible for ensuring that
the device can be operated in the proper manner.
Infrared (IR) remote handset
+/– = Setting
Operating level,
Timer, Temperature,
Fan speed
a = MODE
Operating mode
selector switch
FAN MODE
Ventilation only
COOL MODE
Cooling and ventilation
b = No function
c = TEMP.
Desired interior
temperature
16 °C to 31 °C
Hr.
COOL
MODE
COOL LOW
TEMP.
TIMER
COOL HIGH
COOL
FAN LOW
FAN HIGH
°C
TEMP.
MODE
TIMER RESEND
ON / OFF
a
d
b
e
f
g
c
Saphir compact
d = No function
e = TIMER off
Set timer to 1 to 15 hours
f = RESEND
Send the settings of the remote control
to device again
g = ON / OFF
On / Off switch
Taking into operation
Before switching on, be sure to check that the campsite pow-
er supply fusing is sufficient for 700 W (230 V – at least 3 A).
In order to prevent the power cable for the caravan from
overheating (minimum cross-section 3 x 2.5 mm²) the
cable drum must be fully unwound.
The remote handset must always be pointed at the infrared (IR)
receiver in order to execute the individual switching commands.
1. Switch the Saphir compact on using button “g” on the
remote handset. The “COOL MODE” that was previously
selected using the remote handset is automatically used.
2. Set the desired operating mode using the button “a”.
FAN MODE: Ventilation only without cooling.
Select the required fan speed FAN LOW or
FAN HIGH using the “+” and “–” buttons.
COOL MODE: Cooling with 3 levels.
The room temperature can be individually
adjusted. The green indicator lamp on the
receiver indicates that the compressor is
running. Select the required cooling setting
COOL LOW, COOL or COOL HIGH using
the “+” and “–” buttons.
The COOL LOW setting acts as a sleep function. The
internal and external fans operate at a slower speed in
this mode in order to minimise the amount of noise that is
generated.
3. Select the required room temperature using the “c”, “+”
and “–” buttons.
When the room temperature that was selected using the
remote handset is reached in cooling mode, the compressor
switches off and the green indicator lamp in the receiver goes
off. The circulation fan continues to run in order to provide
ventilation. If the room temperature setting is exceeded the
device automatically reverts to cooling mode.
Switching off
To switch off, press the button “g” on the remote control
once again.
If the air conditioning unit is switched on again within
approximately 3 minutes, the green indicator lamp
flashes. The recirculated air fan runs, and the compressor is
activated after a maximum of 3 minutes.
Timer off
The air conditioning unit deactivation time can be set up to
15 hours in advance using the integrated timer, starting from
the current time.
To carry out programming, first switch the device to remote
control mode with the switch “g”.
Then set the operating mode and the room temperature using
buttons “a”, “c”, “+”, and “–”.
Then select the required deactivation time (1 – 15 hours) using
the “e” button (TIMER).
The programming is not active unless the air conditioning
unit is switched on. The remote handset can be deactivated
by covering the infrared transmitter on the front of the remote
handset. This prevents unintentional air conditioning unit de-
activation and accidental deactivation time reprogramming.
IR receiver and manual on / off
There is an additional pushbutton on the receiver (m), with
which the unit can also be switched on and off without the
remote control (e.g. with a ballpoint pen).
If the unit is switched on using
this pushbutton, the system
is automatically reset to the
factory settings (COOL HIGH,
TEMP. 21 °C).
m
LED 2
LED 1
Saphir compact
Operating indicator
LED 1 green illuminated Cooling (COOL LOW, COOL
or COOL HIGH)
LED 1 green short flash The recirculated air fan runs,
and the compressor is also
activated after a maximum of
3 minutes
LED 1 green flashes briefly Only during operation with
power inverter: Waits until
engine starts or function is
changed using remote handset
LED 2 red short flash Data transfer in progress or
supply voltage being
connected
LED 2 red illuminated Fault
Operating instructions
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

truma-saphir-compact

Suche zurücksetzen

  • Warum kommt keine kältere Luft (20 Grad) obwohl der Kompressor läuft Eingereicht am 22-7-2022 17:14

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Saphir compact wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info