Cold air distribution and circulating air
return feed
Cold air distribution
A KR 65 Ø 65 mm (8) cold air duct with at least one outlet
must be connected to each of the three cold air emitters of
the unit (5, 6 and 7).
Slide the cold air ducts (8) into the cold air emitters of the unit
and route to the air outlet nozzles. Truma can supply a sound
muffler for installing in the cold air system (part no. 40040-
60100) as an accessory for reducing the noise level.
The RL rectangular air outlets (part no. 40280-01) with the
ANH connecting piece (part no. 40920-02) are particularly
suitable for use as cooled air outlets into the vehicle interior.
The cold air distribution system is individually designed
for each vehicle model using a modular principle. A wide
range of accessories is available for this purpose.
In order to achieve the best possible cooling power, we
recommend:
Route cold air pipes to air vents as short and straight as
possible.
The total accumulated length of cold air duct that may be
used is 15 m.
Connect the longest cold air duct (max. 8 m) to the marked
cold air outlet (q), since this has the most air throughput.
q
To prevent condensation, do not route cold air ducts in the
vicinity of incoming outside air (or behind the refrigerator).
Circulating air return
The circulating air is drawn in again by the unit, either through
an additional rectangular air grille (1 – part no. 40040-29200)
or 3 round air grilles (part no. 40040-20400), e.g. in the stow-
age box wall or via several smaller openings with a total area
of at least 300 cm².
Important note
To ensure trouble-free air exchange, the air infeed from the
interior of the vehicle to the installation location must be
located in the immediate vicinity of the device. If appropri-
ate, covers are to be fitted, in order to avoid the circulating air
return being impeded by stowed objects.
If the equipment cannot be installed in close proximity,
Truma can provide a flexible air intake (part no. 40090-
59100) as an accessory.
Installing the infra-red receiver
The receiver (9) is to be fitted for preference on the clothes
cabinet in such a way that the remote control can be pointed
at it without any hinderance (length of connection cable 3 m).
If necessary, a 3 metre cable extension can be supplied
(part no. 40090-89100).
If the receiver cannot be flush-mounted, Truma can
provide an on-surface frame (10 – part no. 40000-52600)
as an accessory if required.
Drill a hole 55 mm in diameter. Lead the cable through from
behind and secure the receiver with 4 screws (11). Then at-
tach the cover frame (12), route the cable to the air condition-
ing unit and connect to the unit at the side.
Ø 55 mm
13
13
12
10
9
11
Truma offers side parts (13) in eight different colors for
finishing the cover frames (12) in a visually pleasing way.
Please ask your dealer.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

truma-saphir-vario

Suche zurücksetzen

  • Sobald man den landstrhm einstekt läuft das gebläse
    Eingereicht am 22-7-2020 12:58

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Saphir Vario wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info