484639
10
Zoom out
Zoom in
Vorherige Seite
1/47
Nächste Seite
Once the room temperature
set on the control panel has
been reached, the burner
switches back to the lowest
stage, and heats the water
content to 60°C. The yellow
monitor lamp (g) indicates
the heating-up phase is in
progress, and goes out once
the appropriate water tem-
perature has been reached.
Heating without
water temperature
monitoring
1. Set the rotary switch to the
operational setting „d“.
2. Turn the rotary switch (a)
to the desired thermostat
setting (1 – 9). The green
indicator lamp (b) illuminates
and indicates the room
temperature setting.
The device automatically
selects the setting that is
required in accordance with
the difference between the
temperature setting and the
current room temperature.
Once the room temperature
set on the control panel has
been reached, the heating
will switch off.
If the boiler is filled, the water
will automatically be heated
at the same time. The water
temperature is then depend-
ent on the heating output
being given off, and the
duration of heating required
to reach the desired room
temperature.
In this operational mode,
the yellow monitor lamp
(g – boiler heat-up phase)
only lights up if the water
temperature is below 5°C!
Heating operation
is basically possible
without restriction with or
without water content.
Heating with drained
water system
1. Set the rotary switch to the
operational setting „d“.
2. Turn the rotary switch (a)
to the desired thermostat
setting (1 – 9). The green
indicator lamp (b) illuminates
and indicates the room
temperature setting.
The device automatically
selects the setting that is
required in accordance with
the difference between the
temperature setting and the
current room temperature.
Once the room temperature
set on the control panel has
been reached, the heating
will switch off.
In this operating mode the
yellow indicator lamp (g –
boiler heat-up phase) only
illuminates at room tempera-
tures of less than 5°C!
Switching off
Gas operation“
Switch heating system off at
the rotary switch (f).
Always drain water con-
tents if there is a risk of
frost!
If the appliance is not to be
used for a prolonged period,
close the quick-acting valve
in the gas supply line and
turn off the gas cylinder.
Red indicator lamp
„Failure“
In the event of a fault, the red
monitor lamp (h) will light up.
Please consult the Trouble-
Shooting list for possible
causes.
Release is effected by
switching the system off and
then on again.
Opening the window
switch and closing it
again is the equivalent to
switching off/on at the con-
trol panel (e.g. performing a
fault reset)!
230 V electrical
operation (450 W/2 A)
– Trumatic C EL only –
(hot water only)
Trumatic C EL
230 V ~
k
j
j = Rocker switch „On“
k = Rocker switch „Off
Switch boiler on at the oper-
ating point (j). The indicator
lamp indicates that the
device is in operation.
When using vehicle-specific
switches: refer to operating
instructions of vehicle
manufacturer.
The water temperature
cannot be selected,
automatic temperature limi-
tation at approx. 60°C! For a
faster heating up period the
appliance can be simultane-
ously operated with gas and
electrical power.
Maintenance
The water container used is
made of stainless steel, which
is foodstuff-compatible.
Use wine vinegar for descal-
ing the water heater, this
being introduced into the ap-
pliance via the water supply.
Allow the product to react
and then thoroughly flush
out the appliance with plenty
of fresh water. To sterilise
the water we recommend
„Certisil-Argento“. Other
products, particularly those
containing chlorine are
unsuitable.
To avoid infestation by micro-
organisms, the boiler must
be heated to 70°C at regular
intervals (only possible in
winter operation).
The water can be
heated to up to 70°C de-
pending on the heating pow-
er that is required to achieve
the room temperature.
Do not use the water as
drinking water!
Fuses
The device and control panel
fuses are on the electronic
control unit on the device.
Device fuse:
6.3 AT – slow –
Control panel fuse (F3):
1.6 AT – slow –
The fine-wire fuse must only
be replaced by a fuse of the
same design.
General safety
notes
If the gas system is leaking
or if there is a smell of gas:
extinguish all naked flames
do not smoke
switch off the appliances
shut off the gas cylinder
open windows and door
do not actuate any
electrical switches
have the entire system
checked by an expert!
Repairs may only
be carried out by an
expert!
A new O-ring must always
be installed after dismantling
the exhaust duct!
1.
Any modifications to the
unit (including the exhaust
duct and the cowl) or the use
of spare parts and acces-
sories that are important to
the operation of the system
(e.g. the time switch) that are
not original Truma parts and
failure to follow the installa-
tion and operating instruc-
tions will cancel the warranty
and indemnify Truma from
any liability claims. It also
becomes illegal to use the
appliance, and in some coun-
tries this even makes it illegal
to use the vehicle.
2. The operating pressure of
the 30 mbar gas supply must
correspond with the operat-
ing pressure of the device
(see data plate).
3. Liquid gas systems must
comply with the technical
and administrative regula-
tions of the respective coun-
try of use (e.g. EN 1949 for
vehicles or EN ISO 10239 for
boats in Europe). National
directives and regulations
(e.g. DVGW worksheet G 607
for vehicles and G 608 for
boats in Germany) must be
complied with.
The testing of the gas sys-
tem must be repeated every
two years by a qualified
specialist and, if appropriate,
confirmed on the inspection
certificate (in Germany, f. ex.
DVGW Worksheet G 607 for
motor vehicles or G 608 for
boats).
The vehicle owner is
always responsible for
arranging the inspection.
Pressure regulating devices
and hoses must be replaced
with new ones no more than
10 years after their date of
manufacture (every 8 years
10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

trumatic-c-4002

Suche zurücksetzen

  • Wo befindet sich das Batteriefach für den Gerätezünder. Gerät heizt nur Wasser aber nicht den Raum. Nach einschalten ca 15/20 Sekunden ertönt ein Klick und darauf erscheint gleich die rote Lampe. Eingereicht am 20-11-2021 07:00

    Antworten Frage melden
  • Guten Tag
    Ich habe eine Trumatic c 4002 Version 2006
    Wo befindet sich die Batterie des Zünders?
    Gerät heizt nicht (ausser Wasser) nach einschalten 15//20 Sekunden Klick, dann erscheint rote Lampe.
    Liebe Grüsse Walti Eingereicht am 20-11-2021 06:55

    Antworten Frage melden
  • Kann man die trumatic c4002 auch bei nur Warmwasser nur mit Strom betreiben?? Eingereicht am 7-5-2020 15:15

    Antworten Frage melden
  • Nach Winterpause Wasser befüllt, kommt kein Warmwasser Eingereicht am 20-4-2018 14:53

    Antworten Frage melden
  • habe trumatic c4002 .meine truma spriegt so bei 6-7 erst an..sonst lauft sie top.
    was muss ich machen
    Eingereicht am 30-10-2017 20:05

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic C 4002 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info