Trouble-shooting list
Fault Cause Rectification
No LED is shining, the device
is switched on and is supplied
with operating current.
Automatic restart is
blocked, e.g. after a power
failure.
Reset (fault reset) by switching off, waiting 5 seconds
and then switching on again.
After switching on (winter and
summer operation) none of the
LEDs are lit.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V battery voltage, charge if necessary.
Check all electrical plug connections.
Check the unit or vehicle fuse and replace if necessary
(see fuses).
The green LED comes on when
the unit is switched on but the
heater does not operate.
The temperature setting on
the control panel is lower
than the room temperature.
Select higher room temperature at the control panel.
After switching on the heating
system, the green LED shines
and
the red LED flashes with 5 Hz,
the red LED flashes with 1 Hz,
the red and the yellow LEDs
flash alternately with 1 Hz.
Open window above cowl
(window switch).
Under-voltage.
Battery voltage is too low
< 10.0 V.
No 230 V operating
voltage.
230 V fuse defective.
Overheating protection has
activated.
Threatening under-voltage.
Battery voltage is too low
< 10.4 V.
There is a threat of under-
voltage when heating up
the water.
Battery voltage is too low
< 10.4 V.
Close window.
Charge battery. If necessary replace old battery.
Re-establish 230 V operational voltage.
Replace 230 V fuse.
Reset overheating protection. Allow heater to cool,
remove connection cover and press reset button.
Charge battery.
Charge battery.
After the heater is switched on,
the green LED is lit and the red
LED blinks.
Electronics are defective. Please contact the Truma Service Centre.
Approximately 30 seconds after
the heater is switched on, the
red LED is lit.
Gas cylinder or quick-clo-
sure valve in the gas line is
closed.
Combustion air infeed or
exhaust outlet is sealed.
Check gas supply and open valves.
Inspect openings for contamination (slush, ice, leaves,
etc.) and remove contamination if necessary.
After operating for a longer pe-
riod of time, the heater switches
to failure.
Summer operation with
empty water tank.
Hot-air outlets blocked.
Recirculated air intake
blocked.
Gas pressure regulator
iced up.
Butane content in the gas
cylinder too high.
Switch device off and allow to cool. Fill boiler with
water.
Check individual outlet apertures.
Remove blockage from recirculated air intake.
Use regulator heating (EisEx).
Use propane (at temperatures below 10 °C in particu-
lar, butane is unsuitable for heating purposes).
Green and red LEDs flash (with
5 Hz) after the heating system
has been switched off.
Green LED flashes (with 5 Hz)
after the heating system has
been switched off.
Unit was switched off dur-
ing failure. After-running
is active in order to reduce
the unit’s temperature.
After-running is active in
order to reduce the unit’s
temperature.
After-running will switch off after a few minutes. Only
at that time will a failure reset be possible (switch off
and then back on).
No failure. After-running will switch off after approxi-
mately 5 minutes.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic Combi 4 E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info