484616
14
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
14
Draining the water heater
Switch off power to water pump (main or pump switch).
Open hot water taps in kitchen and bathroom.
Turn the rotary switch on the drain valve (FrostControl) by 180°
until it engages, whereby the push button moves out and the
drain valve opens.
The boiler is now drained directly to the outside via the drain
valve. Place a bucket beneath the outlet to check whether the
water content has completely drained away (10 litres). There
shall be no claims under guarantee for damage caused
by frost!
Maintenance
Only original Truma parts may be used for maintenance and
repair work!
We recommend the Truma system care set for cleaning, dis-
infecting and looking after the boiler. Other products – in par-
ticular products containing chlorine – are unsuitable.
The effectiveness of the use of chemicals to combat microor-
ganisms in the unit can be increased by heating the water in
the boiler to 70 °C at regular intervals.
Move the rotary switch on the control panel to position (c –
summer operation) 60 °C. The green (b) and yellow (g) LEDs
light up.
Once the water in the boiler has reached a temperature
of 60 °C, the burner will switch off and the yellow LED (g)
will go out. The unit must stay switched on for at least 30 min-
utes and no warm water may be removed. The residual heat in
the heat exchanger will heat the water up to 70 °C.
Fuses
The unit’s fuse is located on the electronics under the connec-
tion cover. Replace the unit’s fuse only with an identical fuse.
Device fuse: 10 A – slow – (T 10 A)
T 10 A
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
Technical data
(determined in accordance with EN 624 or Truma test
conditions)
Device category
I
3 B/P
in accordance with EN 437
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water contents
10 litres
Heating up time from approx. 15 °C to approx. 60 °C
Boiler approx. 20 minutes (measured according to EN 15033)
Heater + boiler approx. 80 min.
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Rated thermal output (automatic output levels)
Combi 4: 2000 / 4000 W
Combi 6: 2000 / 4000 / 6000 W
Gas consumption
Combi 4: 160 – 320 g/h
Combi 6: 160 – 480 g/h
Readiness-heat power requirement Combi 4 / Combi 6: 5.2 g/h
Air delivery volume (free-blowing without hot-air pipe)
Combi 4: with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Combi 6: with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + boiler
Combi 4: Short-term max. 5.6 A
(average power consumption 1.1 A)
Combi 6: Short-term max. 5.6 A
(average power consumption 1.3 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional): maximum 0.4 A
Weight (without water contents)
Heater unit: 14.0 kg
Heater unit with peripheral devices: 14.5 kg
The right to effect technical modifications is reserved!
Dimensions
450 mm
510 mm
300 mm
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic Combi 6 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info