Exhaust duct
With the Trumatic E 2400 E only use the Truma exhaust duct
AA 24 (part no. 39420-00) for the installation with wall cowl
and the combustion air supply duct ZR 24 (part no. 39440-
00) as the appliance has only been tested and approved with
these ducts.
A new O-ring must always be installed after disman-
tling the exhaust duct!
Permissible duct lengths
1. Interior installation with wall cowl (refer to installation
variant 1, page 2):
Duct lengths of up to max. 70 cm can be routed as as-
cending duct in any way required, or descending by max.
30 cm.
Duct lengths from 70 cm to max. 150 cm must be rout-
ed as ascending duct with an ascending angle of min. 45°.
2. Under-floor assembly with wall cowl (refer to installation
variant 2, page 2):
Cowl double duct length max. 70 cm, routed as ascend-
ing duct in any way required or descending by up to 30 cm.
Interior installation using the wall cowl kit
Refer to installation variant, Fig 1 (page 2).
Assembly of wall cowl
Assemble wall cowl on a surface which is as flat as possible
and which is exposed to wind from all directions. Drill an
opening (8) measuring 70 mm in diameter (pack wood into
hollow spaces in the area of the cowl opening). Use the pro-
vided rubber seal (10) for sealing. In the event of structured
surfaces, coat with plastic body sealant – do not use silicone.
In the event of a greater wall thickness, first connect the
exhaust double duct to the cowl from the outside.
Slide rubber seal (10) and clamp (4) onto the cowl inner part (11).
Coat serrated connection fitting (9) with plastic body sealant
– do not use silicone! – and slide over combustion air supply
duct (5).
1
4
2
3
2a
Press end of ex-haust duct (1) together so that winding
touches winding, slide over the O-ring (2a) on the connection
fitting (2) up to the collar (3 – cowl bend pointing upward) and
tighten clamp (4) in such a way that the knurled edge of the
clamp encloses the collar.
Fasten cowl inner part (11) with 3 screws (12 – observe instal-
lation position! The Truma lettering must be at the bottom).
Mount cowl outer part (13) and screw on with 2 screws (14).
Always install a new O-ring following any disassembly!
Fastening the appliance
Depending on the installation position, bolt on the appliance
using fastening strap (a) or mounting brackets (b).
Fasten exhaust double duct to the wall using duct clamp
ZR 24 (c), if necessary (parts to be found in enclosed kit).
Double cowl duct connection to the
heating appliance
Press end of ex haust duct (1) together so that winding touch-
es winding. Slide clamp (4) over exhaust duct (1). Slide ex-
haust duct over O-ring on the connection fitting (2) up to the
collar (3). Attach with clamp (4) in such a way that the knurled
edge of the clamp encloses the collar. Fasten combustion air
supply duct (5) on the connection fitting (6) using clamp (7).
Always install a new O-ring following any dis-assembly!
Under-floor assembly with wall cowl kit
Refer to installation variant fig. 2 (page 2).
Install wall cowl on as flat a surface as possible on an outside
wall (vehicle apron, refer to “Interior installation using the wall
cowl kit”).
If the wall cowl is fitted with fixing brackets or similar
below the floor, the vehicle floor must be airtight and
the waste gas must always be guided up to the side wall (see
„Choosing the installation place“).
Fastening the appliance
Screw the 3 fastening strips (1, 2 + 3) to the appli-ance. Screw
appliance to vehicle floor with the strips 1 + 2. Fasten assem-
bly bracket (4 – special equipment Part. no. 39050-74000) to-
gether with strip (3) and screws (5). Place lock washers under
all screw heads and nuts.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

trumatic-e-2400-e

Suche zurücksetzen

  • Ich benötige die Bedienungsanleitung für meine neue Trumatic E 2400 Eingereicht am 23-4-2018 15:18

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic E 2400 E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trumatic E 2400 E

Trumatic E 2400 E Bedienungsanleitung - Deutsch, Englisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info