Installation instructions
The installation and repair of the appliance is only to be
carried out by an expert. Read the installation instruc-tions
carefully prior to starting work and observe the instructions!
The consequences of failing to adhere to the in-
stallation instructions or installing the equipment
incorrectly are potentially fatal!
Intended use
This device was designed for installing in vehicles (motor
homes, cars and commercial vehicles). Other applications are
permitted after prior consultation with Truma.
Installation inside busses (vehicle classes M2 and M3) is not
permitted.
Vehicles EX/II and EX/III
Combustion heaters for gaseous fuels are not permitted.
Approval
Declaration of conformity
The Trumatic E 2400 E has been tested by the DVGW and
complies with the gas equipment directive (90/396/EEC) and the
other applicable EC directives. The following CE Product Ident.
No. is available for EU countries: CE-0085APO0008.
The heater complies with heater directive 2001/56/EC and
supplements 2004/78/EC and 2006/119/EC and bears the type
approval number: e1 00 0144.
The heater complies with vehicle engine interference sup-
pression directive72/245/EEC with supplements 2004/104/EC,
2005/83/EC and 2006/28/EC and bears type approval number:
e1 03 2605.
The heater complies with EMC directive 89/336/EEC and low
voltage directive 72/23/EEC.
The heater is approved for installation in motor vehicles for
transporting passengers (motor caravans in vehicle class M1)
that have no more than 8 seats excluding the driver’s seat and
for commercial vehicles (vehicle class N).
The first year of operation must be marked on the type
plate.
Regulations
Any modifications to the unit (including the exhaust duct and
the cowl) or the use of spare parts and accessories that are
important to the operation of the system (e.g. the time switch)
that are not original Truma parts and failure to follow the in-
stallation and operating instructions will cancel the warranty
and indemnify Truma from any liability claims. It also becomes
illegal to use the appliance, and in some countries this even
makes it illegal to use the vehicle.
In-vehicle installations must comply with the technical and ad-
ministrative regulations of the respective country of use. The
national rules and regulations (e.g. DVGW Worksheet G 609
Draft and VdTÜV Code of Practice 757 in Germany) must be
observed.
The relevant employer’s liability insurance association accident
prevention regulations must be observed in Germany for vehi-
cles used for commercial purposes (BGV D 34).
In other countries always observe the respectively valid
regulations.
For further details on the rules and regulations in the respec-
tive country of designation, please contact our agencies
abroad (see Truma Service Booklet or www.truma.com).
Notes on the installation in commercial vehicles
When installing the heater in special vehicles (e.g. vehicles for
transporting hazardous goods), the respective regulations for
such vehicles must be observed.
Notes on installation in driver's cab
For appliances with ex-haust ducts under the vehicle floor, the
exhaust cowl must extend into the area of the side or rear wall
of the cab or vehicle, in order to make sure exhaust gas does
not enter the inside of the vehicle.
Model-related assembly instructions can be obtained from
Truma.
In Germany, for tank vehicles carrying hazardous goods in the
field of application covered by the ADR, the appliance is only
approved with the Truma control unit.
Choice of location
Always install the appliance and its exhaust duct in such a
way that it is always easily accessible for service work and can
be removed and installed easily.
For evenly distributed heat-ing, the installation of the appli-
ance should be as much in the centre of the vehicle as pos-
sible (or under the vehicle), and in such a way that the air
distribution ducts can be routed with approximately the same
length.
The cowl must be placed in such a way that exhaust gas
cannot find its way into the vehicle interior.
The wall cowl is to be fitted in such a way that no tank nozzles
or tank ventilation apertures are located within 500 mm (R) of
it. In addition, no air discharge apertures for the living area or
window openings may be located with 300 mm (R) of it.
300 mm
300 mm
R
If the cowl is being installed directly beneath a window
that can be opened, it must be equipped with an elec-
tric switch. The gas unit must automatically switch itself off
using the Truma automatic shut-off facility if the window is
opened (special accessory part no. 39050-00800).
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

trumatic-e-2400-e

Suche zurücksetzen

  • Ich benötige die Bedienungsanleitung für meine neue Trumatic E 2400 Eingereicht am 23-4-2018 15:18

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic E 2400 E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trumatic E 2400 E

Trumatic E 2400 E Bedienungsanleitung - Deutsch, Englisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info