To calibrate the gas valve (standard procedure MANU: it is possible to
deviate from the value set by approximately +/-1.5 mbar) carry out the
following operations:
hPlace the electric switch of the system to off
hRemove the casing by unscrewing the fastening screws located at the
bottom of the water heater and detached the casing from the top
hRemove the cover that closes the service inlet (located on the
shelf - Fig 11) and insert through the hole the silicon pressure
gauge tube
hLoosen by approximately two turns the screw of the pressure tap
downstream of the gas valve and connect the pressure gauge to it
hCarefully close the casing and place the electric switch of the sys-
tem to on
hAccess the Calibration Menu
hOpen the hot water tap and wait until ignition of the burner.
Upon activation of the menu will appear rst the word Ma and then the
word to to compose Manu and will appear, indicating that the
water heater is operating at maximum capacity.
hTurn the knob until visualize on the pressure gauge the maximum
burner pressure (see data table)
hTo store the value press the reset button
hPress the reset button to select the next lowest setting value
hTurn the knob until visualize on the pressure gauge the minimum
burner pressure (see data table)
hTo store the value press the reset button
hPress the reset button until MENU’ ashing, release the button:
the display shows
hPress again the reset button until the display shows MENU’ ashing,
release the button: the display shows the set point temperature
hClose the hot water tap.
The calibration operation ends automatically after 15 minutes of
inactivity or in the case of overheating (67°C)
Alarm history menu
This feature allows displaying of the last 10 errors that have occurred on
the appliance.
Upon activation of the menu, the gures (index of the last stored
error), the error code and the word (es: => => ) will
appear alternately.
Turning the knob it is possible to scroll through the errors index. Display
ranges from the most recent to the earliest.
If the user pauses, the display shows the letters AL to indicate access
within the errors history menu.
Press the reset button until MENU’ ashing, release the button: the di-
splay shows .
Press again the reset button until the display shows MENU’
ashing, release the button: the display shows the set point tem-
perature.
Info menu
This feature allows displaying:
hLast version of software review
hHot water temperature in direct
hHot water quantity in direct (l/min).
This menu is active during all the production of instant hot water.
Exiting the menu takes place automatically after 15 minutes of
inactivity or by pressing the reset button.
Fig. 25 - “Alarm History Menu” Activation
Fig. 24 - “Calibration Menu” Activation
Fig. 26 - “Info Menu” Activation
Eco
Eco
Eco
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für TTulpe C-Meister 11 P37 Eco wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von TTulpe C-Meister 11 P37 Eco

TTulpe C-Meister 11 P37 Eco Bedienungsanleitung und Installationsanweisung - Deutsch - 24 seiten

TTulpe C-Meister 11 P37 Eco Bedienungsanleitung und Installationsanweisung - Holländisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info