-When the unit operates in the cooling operation, drying operation, the ambient temperature
sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop
operating for 10 minutes or the coil temperature up to 7, the unit restart to cool operating
mode.
-When the unit operates in the drying operation, once the coil temperature sensor senses the
temperature of the evaporator is below 40 and the differential temperature between coil
temperature and room temperature is below 19 after the compressor operation for
20minutes, the unit start defrosting for 5 minutes and the power indicator blinking. Overload
Protection - In the event of a power loss, to protect the compressor there is a 3-minute delay
until the compressor restarting.
DRAINAGE
Self- evaporating system
The self-evaporating system uses the collected water to cool the condenser coils for
better efficient performance. It is no need to empty the drainage tank in cooling
operation except in drying operation and high humidity conditions. The condensate
water evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying and heating operation,
please connect the attached drain hose to the unit. Condensate water can be
automatically flow into a bucket or drain by gravity.
-Switch off the unit before operating.
-Remove the plug of the water outlet
opening, and keep it in safe area.
-Securely and properly connect the drain
hose and make sure it is not kinked and
clear of obstruction.
-Place the outlet of hose over a drain or
bucket and ensure that water could freely
flow out of the unit.
-Do not submerge the end of hose into
water; otherwise it can cause "Air Lock" in
the hose.
Remove the rubber sealing plug
Continuous drain hose
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose
downward toward the floor. It is appropriate that the degree of inclination should exceed 20
degrees.
Straighten the hose to avoid a trap existing in the hose.
6. CLEANING AND CARE
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the
efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not
operate the unit without an air filter, or the evaporator may be contaminated.
-Press POWER button to switch off the unit and unplug the power cord.
-Remove the filter mesh from the unit.
-Use a vacuum cleaner to suck dust from the filter.
-Turn the filter over and rinse the air filter under running water. Let the water run through
the filter in the opposite direction of air flow. Set aside and allow the filter to air dry
completely before reinstalling.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Turbionaire Revigo 10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info