557352
4
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
Rapid Exhaust feature is a standard item on the TUSA B.C.J.’s allowing the diver to
vent air rapidly from the B.C.J.
Procedure for activating valve is as follows:
1. Pull gently on forward Inflator Assembly to activate
Exhaust Valve. Maintain forward pressure until enough
air has been exhausted to reach desired buoyancy.
Release pressure to close valve.
6 7
GB
To Your Regulator
HAND-SCREW in threaded end of the QD Hose into Low Pressure Port of Regulator.
Tighten gently but firmly with a 15mm hexagonal key. The threaded connection of
the QD hose to the pressure reducer is a standardized connection 3/8" UNF. Please
refer to the User’s Manual of your regulator for identification of LP outlets.
Check your system before dive: a low pressure gauge connected to LP Ports must
not read over 1.2MPa (12bar), and under 0.8MPa (8bar) if tank is full.
It is recommended that your TUSA dealer installs your QD Hose on your regulator.
WARNING: Do not connect QD Hose to Regulator High Pressure(H.P.) Port.
Injury to diver and equipment may result.
To Your B.C.J. (Fig. 1)
Connect QD Hose Inflator by pulling Quick-Disconnect Collar back with thumb and
forefinger, while pushing Hose Coupling onto Inflator Plug. Release Collar when
Coupling is engaged fully. Pull gently but firmly on Hose to check if Coupling is
securely joined to Plug. To disconnect Inflation Hose from Inflator, pull Quick-
Disconnect Collar back and disengage Coupling from Plug
(Fig. 1)
Attach the “Low
Pressure Quick
Disconnect Hose”
to the inflator plug.
(Fig. 2)
Secure the airway
together with QD
Hose to the Hock &
Loop hose retainer.
(Fig. 7)
Rapid Exhaust Deflation (Fig. 7)
B.C.J. DEFLATION
AIRWAY SYSTEM
Airway Systems are standard on all TUSA B.C.J. ’s
Low Pressure Quick Disconnect(QD) Hose Installation
Setting the low pressure hose (APA type)
Connect the plug for the coupler for the regulator BCJ low pressure hose, then fit in
the low pressure hose in the groove on the side of the inflator hose as in Photographs
3 and 4. This arranges the hose neatly and makes it easier to handle and makes it
easier to mount and remove the BCJ.
Inflator setting position (APA type)
The recommended APA inflator setting position is the same as for a regular inflator.
(Fig. 5)
Of course, normal exhaust operations and use of the Rapid Exhaust Deflation by
pulling the APA inflator main unit are both possible. When primarily using the rapid
exhaust function with the APA exhaust button, there is also an APA inflator setting
position that uses the BCJ hose holder to fasten with the APA exhaust button right at
hand. (Fig. 6)
(Fig. 5) (Fig. 6)
(Fig. 3) (Fig. 4)
BCJ(CE)002-021 GB 10.11.17 9:35 AM ページ 6
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tusa Buoyancy Compensator Jacket wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info