- Place a container by the outlet of the drain pipe in order to catch the condensed water, (fig. H- step C).
- Put the warm air expulsion pipe in the parking position (fig. N).
- Select the dehumidification function (
).
- As much as 31,2 litres of water can be taken out of the air every 24 hours, depending on the ambient
conditions.
Attention!
This apppliance is not suitable for dehumidification at ambient temperatures of below 18This apppliance is not suitable for dehumidification at ambient temperatures of below 18
This apppliance is not suitable for dehumidification at ambient temperatures of below 18This apppliance is not suitable for dehumidification at ambient temperatures of below 18
This apppliance is not suitable for dehumidification at ambient temperatures of below 18°
C.C.
C.C.
C.
When you change back to the «Cooling» function, put the plug back into the drainage nozzle on the outdoor unit.When you change back to the «Cooling» function, put the plug back into the drainage nozzle on the outdoor unit.
When you change back to the «Cooling» function, put the plug back into the drainage nozzle on the outdoor unit.When you change back to the «Cooling» function, put the plug back into the drainage nozzle on the outdoor unit.
When you change back to the «Cooling» function, put the plug back into the drainage nozzle on the outdoor unit.
Should you fail to do so, the appliance will shed water produced by condensation during the cooling process.Should you fail to do so, the appliance will shed water produced by condensation during the cooling process.
Should you fail to do so, the appliance will shed water produced by condensation during the cooling process.Should you fail to do so, the appliance will shed water produced by condensation during the cooling process.
Should you fail to do so, the appliance will shed water produced by condensation during the cooling process.
AIR PURIFICATION
- On this setting the air inside the room is recirculated through purifying filters.
-The appliance includes a basic filter with a double active purifyng filter for: smoke, dust, pollen and bacteria.
- Put the warm air expulsion pipe in the parking position (fig. N).
- Select the ventilation speed: Maximum (
) or silent ( ).
- We recommend leaving the filters installed, independently of the setting chosen (refrigeration,
dehumidification or air purification) This will provide you with a more efficient purifying action.
HEATING (AA4020)
In the ( ) position the appliance will heat the air in the room while it filters it.
- Put the warm air expulsion pipe in the parking position (fig. N).
- Select the heating function (
).
- Set the thermostat to the desired temperature. Once the room reaches the said temperature the appliance
will switch itself off automatically and come back on when it drops by 2-3ºC.
Attention!Attention!
Attention!Attention!
Attention!
Do not cover the appliances air intakes or outlets.Do not cover the appliances air intakes or outlets.
Do not cover the appliances air intakes or outlets.Do not cover the appliances air intakes or outlets.
Do not cover the appliances air intakes or outlets.
CLEANING & MAINTENANCE
Cleaning and replacing the purification filters
- The inside unit is fitted with a basic air filter (fig A,5), which will require cleaning from time to time. To do
this it should be washed under running water, dried and put back.
- The set of purifying filters (fig A,6) will have to be replaced each year. Replacement filters can be obtained
from your local supplier. Always use original Ufesa replacement parts.
Replacement filters: RKZ09013 Replacement filters: RKZ09013
Replacement filters: RKZ09013 Replacement filters: RKZ09013
Replacement filters: RKZ09013
- Fit the new filters as shown in (figures O,P).
- Only place one set of filters over the base filter in order to maintain the cooling effect.
Cleaning the appliance
- The appliance can be cleaned down with a cloth or sponge, warm water and a mild detergent.
- Never use hot water (more than 40º C), benzene, gasoline, acids or brushes, and try to prevent water from
getting inside the appliance. Do not clean the appliance down with a hose.
- Clean the outdoor unit before it is put away. To do this, spray a little water on to the heat exchanger.
AA4000/4020/8000 13/9/04, 10:2613
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ufesa AA8000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info