General Information
When the appliance is installed on existing systems, ensure
yourself that:
- Theueoutletpipeissuitableforcondensingboilers,for
the temperature of the products of combustion, calculated
and manufactured according to the regulations in force. It
must be installed as much as possible in a straight line,
tested for soundness, insulated and must not have any
occlusions or restrictions.
- Theueoutletpipehasaconnectionforthedischargeof
condensate.
- The boiler room has a suitable outlet for the discharge of
condensate produce by the boiler.
- Theelectricalsystemhasbeenttedincompliancetothe
specicnormsandtheworkhasbeencarriedoutbya
competent person.
- Thecirculationpump’soutput,theheadandowdirection
are suitable.
- The gas feeding supply pipe and the eventual tank are
constructed according to the regulations in force.
- The expansion vessels assure the total absorption of the
dilatationoftheuidcontainedinthesystem.
- The system has been cleaned of impurities and lime scale.
When a Modulex boiler is installed onto an existing
heating system:
In case the replacement of an existing boiler in an old system can
be programmed, it
is necessary to thoroughly
clean out the system with a basic solution.
The system must be cleaned 4 weeks before
the substitution, with the system ring at a
temperature of 35°C to 40°C.
WARNING!
If it is noticed that a new Modulex has replaced,
in an old system the existing boiler without having first perfor-
med what said in the previous paragraph, Do not wash now
the system, as residual products, present in the circuit, could
lead to system gathering in the boiler body, causing damage.
UNICAL recommends contacting a specialised company for
water treatment.
Instead, if installing a Modulex boiler in a new system, it is
still recommended to thoroughly clean out the system with an
adequate product and fit a Y filter with two isolating valves onthe
boiler’s return pipe, so that, when necessary, it can be cleaned.
This filter will protect the boiler from the dirt coming from the
heating system.
When sizing pumps, it is necessary to take into consideration
the pressure losses which occurin the primary circuit.
1.6 - INSTALLATION ON EXISTING HEATING SYSTEMS
1.5 - STANDARD CODES FOR
INSTALLATION
The appliance must be installed in compliance to the instructions
contained in this manual.
Theinstallationmustbe carriedoutby acompetentqualied
engineer, whom will assume the responsibility of complying to
allthelocaland/ornationalregulationspublishedintheofcial
publications, as well as all the applicable codes of practice.
Before installing the appliance please contact the gas supply
company.
The installation must be carried in accordance to the codes of
practice, the regulations and the requirements hereby indicated
which constitute an indicative list, but not a complete one, as
these continue to undergo evolve devolpments.
Moreover, the boiler must be installed in accordance to all the
regulations regarding the boiler room, the building regulations
and the prescriptions regarding central heating plants in force
in the country where the boiler is installed.
The appliance must be installed, commissioned and serviced
according to the regulations in force. This is also valid for the
hydraulicsystem,theueoutletsystemandtheboilerlocation
room.
Failure to comply with these rules will
nullify the warranty
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Unical MODULEX EXT 100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Unical MODULEX EXT 100

Unical MODULEX EXT 100 Installationsanweisung - Holländisch - 57 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info