1 Technical information
Operating altitude: with decompression information: sea level up to approx. 4000m (13 000ft);
without decompression (gauge mode): unlimited
Max displayed depth:
120m (395ft), resolution between 0.8m and 99.9m: 0.1m, >99.9m: 1m
.
The resolution in feet is always 1 foot.
Decompression calculation depth range: 0.8 to 120m (3 to 395ft)
Maximum environment pressure:
13bar (189psi)
Clock: Quartz clock, time, date, dive time display up to 199 minutes.
O2 concentration: Adjustable between 21%O2 (compressed air) and 100% O2
Operating temperature:
-10° to +50°C (14°F to 122°F).
Power supply:
CR2450, recommended brands: PANASONIC, DURACELL, RENATA,
ENERGIZER,
SONY, VARTA.
Life of the battery: 2-3 years or 200-300 dives. Actual life of the battery depends on the quantity
of dives per year, the use of the backlight and the length of the dives. In cold
water the life of the battery is reduced. Not all CR2450 batteries are the same,
and low quality batteries can have very short life.
2 Maintenance
Aladin is virtually maintenance free. All you need to do is to rinse it carefully with fresh water after each use
and to have the batteries changed when needed ->51. To avoid possible problems with your Aladin, the
following recommendations will help assure that it will give you years of trouble free service:
• Avoid dropping or jarring your Aladin.
• Do not allow your Aladin to be exposed to direct, intense sunlight.
• Rinse your Aladin thoroughly with fresh water after each dive.
• Do not store your Aladin in a sealed container; make sure there is free ventila-
tion.
• If there are problems with the water contacts, use soapy water to clean
Aladin
and dry it thoroughly. The surface of your
Aladin
housing can be treated
with silicone grease. Do not apply grease to the water contacts!
• Do not clean Aladin with liquids containing solvent (apart from water).
• Check the battery capacity before each dive ->15.
• If the battery icon appears, replace the battery ->51.
•
Diving with a weak battery: Aladin may stop working during the dive, service
icon and error code "E3" or "E6" appear. Close the dive and replace the bat-
tery ->51.
• On the surface: if service icon and error code "E3" appear, replace the battery
->51.
All error codes other than E3: Aladin must not be used for any further dives.
Take your dive computer to an authorized SCUBAPRO UWATEC dealer.
2.1 Replacing the battery (Battery kit 06.201.919 includes battery and Teflon coated o-ring)
Removing the battery clears all physiological data including saturation. This
means that for a repetitive dive the computer will not compute correctly.
Diving after replacing the battery when there is desaturation time left on the
computer can lead to serious injury or death from decompression sickness.
Change the battery only under these conditions:
• After a dive if you know you will not be diving, flying or going to higher altitude
for the next 48 hours.
• Before a dive if there is no desaturation time left on the computer.
The change must be made with particular care in order to prevent water
from seeping in. The warranty does not cover damages due to an improper
replacement of the battery.