3. Diving with Galileo
of 12 seconds. You can revert to the dive
computer screen at any time by pressing
and holding the right button.
NOTE:
- Profi le, compartment saturation
and pictures can be viewed for a
maximum of 1 minute, after which
the regular dive computer screen
will appear again.
- If any warning or alarm is triggered
while you are viewing the profi le,
compartment saturation or the
pictures, Galileo will immediately
revert back to the dive computer
screen.
3.4.5 Activating the backlight
To activate the backlight, press the right
button (marked LIGHT). The default
duration of the backlight is 6 seconds, but
you can set it between 2 and 12 seconds
in one second increments. You can also
set it to PUSH ON/PUSH OFF, which
means the light stays on until you turn it off
by pressing the button again.
NOTE:
The backlight is not available when
the REPLACE BATTERY warning
appears.
3.5 Diving with MB levels
Microbubbles are tiny bubbles that can
build up inside a diver’s body during any
dive and normally dissipate naturally during
an ascent and on the surface after a dive.
Dives within no-stop time and observance
of decompression stops do not prevent the
formation of microbubbles in the venous
blood circulation. Galileo has been equipped
with an enhanced UWATEC algorithm,
named ZH-L8 ADT MB, to reduce the
formation of these microbubbles.
This enhanced algorithm allows the user
to choose a level of conservatism over and
in addition to the worldwide proven safety
record of the standard ZH-L8 ADT algorithm.
There are fi ve levels of added conservatism
(or MB levels), from L1 to L5, with L5 being
the most conservative and L1 being just a
bit more conservative than the standard
ZH-L8 ADT, here referred to as L0.
Choosing an MB level between L1 and
L5 makes the algorithm more conservative,
therefore the diver will have either shorter
no-stop times or deeper and longer
decompression stops (referred to as
level stops) than when diving with L0.
Consequently the body will either take up
less nitrogen (shorter no-stop dives) or will
be able to off-gas more before returning to
the surface (dives with level stops). Both
work towards reducing the amount of
microbubbles present in the body at the
end of the dive.
Please refer to section 2.3.1 for information
on setting the MB level.
3.5.1 MB Glossary
Deco stop: decompression stop as
requested by L0; mandatory.
L0: baseline algorithm corresponding to
ZH-L8 ADT.
L1: fi rst and lowest level of added
conservatism.
L2: second level of added conservatism.
L3: third level of added conservatism.
L4: fourth level of added conservatism.
L5: fi fth and highest level of added
conservatism.
Level stop: decompression stop as
requested by active MB levels L1 through
L5; not mandatory.
Reduced level stop: decompression stop
as requested by new active MB level, after
an MB level reduction has taken place due
to violation of level stop requirement.
ZH-L8 ADT: UWATEC’s adaptive 8-tissue
algorithm.
ZH-L8 ADT MB: UWATEC’s adaptive
8-tissue algorithm with MB levels (added
conservatism).
48

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für UWATEC Galileo Terra wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von UWATEC Galileo Terra

UWATEC Galileo Terra Bedienungsanleitung - Deutsch - 66 seiten

UWATEC Galileo Terra Bedienungsanleitung - Holländisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info