1 Technical information
Operating altitude: with decompression information: sea level up to approx. 4000 m (13120ft);
w/o decompression, w/o RBT information: usable in gauge mode (at any altitude)
Max. displayed depth: 120m (395 ft), resolution between 0.8 m and 99.9 m: 0.1 m, >99.9 m: 1m
The resolution in feet is always 1 foot.
Do not dive deeper than the limits given by the chosen fraction of oxygen
(nitrogen narcosis, oxygen toxicity).
Never dive deeper than your training qualification (experience) allows you.
Always observe local dive depth restrictions.
Decompression calculation depth range: 0.8 to 120m (3 to 395 ft)
Maximum environment pressure: 13 bar (189 psi)
Clock: Quartz timer, display up to 199 minutes.
O2% Mix: Adjustable between 21%O2 (compressed air) and 100% O2
Operating temperature:
-10° to +50°C (14°F to 122°F).
Power supply: Special battery UWATEC LR07
Life of the battery: 500 to 800 dives, depending on the quantity of dives per year and the use of
the backlight.
Transmitter: High pressure connection: Maximum working pressure: 300 bar (4350 psi)
Life of the battery: up to 1000 dives, max. 3 years without use.
Power supply: User replaceable battery CR2450
2 Maintenance
The tank pressure gauge and the parts of this product used to measure the tank pressure should be serviced
by an authorized SCUBAPRO UWATEC dealer every second year or after 200 dives (whichever comes first).
Aside from that your Smart Z is virtually maintenance free. All you need to do is to rinse it carefully with fresh
water after each use and to have the batteries changed when needed. To avoid possible problems with your
Smart Z, the following recommendations will help assure that it will give you years of trouble free service:
Avoid dropping or jarring your Smart Z.
Do not allow your Smart Z to be exposed to direct, intense sunlight.
Rinse your Smart Z thoroughly with fresh water after each dive.
Do not store your Smart Z in a sealed container; make sure there is free ventilation
.
If there are problems with operating the contacts, use soapy water to clean
Smart Z and dry it thoroughly. The surface of your Smart Z housing can be
treated with silicone grease. Do not apply grease to the water contacts!
Do not clean Smart Z with liquids containing solvent (apart from water).
If the service icon appears, Smart Z must not be used for any further dives.
Take your dive computer to an authorized SCUBAPRO UWATEC dealer.
Take the dive computer to an authorised SCUBAPRO UWATEC dealer in
order to change the batteries. The battery replacement is carried out by a
SCUBAPRO UWATEC
subsidiary. Smart Z is checked for its technical integrity
at the same time. Do not attempt to have the batteries changed by anyone
other than an authorised SCUBAPRO UWATEC dealer.
2.1 Replacing the battery of the transmitter
It is recommended to have the battery of the transmitter replaced by an
authorized
SCUBAPRO UWATEC dealer. The change must be made with
particular care in order to prevent water from seeping in.
The warranty does not cover damages due to an improper replacement of
the battery.
Transmitter battery set (PN 06.201.920): Includes a Type CR 2450 battery and a 26.00 x 2.00 mm
transmitter cap o-ring.
WARNING
WARNING
WARNING
WARNING
116

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für UWATEC Smart COM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von UWATEC Smart COM

UWATEC Smart COM Bedienungsanleitung - Deutsch - 120 seiten

UWATEC Smart COM Bedienungsanleitung - Holländisch - 120 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info