for the type of wall).
-Take the upper part of the structure B (Fig.4) and insert the
3 slots onto the 3 screws that are not completely tightened.
Rotate slightly to t (Fig.4). Drive in the fourth screw X and
tighten the remaining 3 to allow denitive blocking of the
upper part of structure B.
-Take the lower part of the telescopic structure C and insert
it into the upper structure B (Fig.5). Adjust the height by
referring to the amounts X indicated in Fig.14 and block it
using the 8 screws G that are supplied (Fig.6).
Suction version: Fix the exible pipe to the prepared air
evacuation hole (Fig.7).
Filtering version: Connect the air exhaust pipe to the
recirculation air deectorM, and tighten the screwI, asshown
in Fig.8. The carbon lters must be tted inside the suction
hood as shown in Fig.16. There are two dierent types of
active carbon lters: long-lasting regenerable active carbon
lters (washable) (Fig.17) and standard non-regenerable
active carbon lters (Fig.16).
-Take the upper chimney piece and x it to the structure
using the 2 screws A (Fig.9). Join the lower chimney piece
with the upper one and x it carefully using adhesive tape L
(Fig.10A).
-Unscrew the 2 screws O, max 3 mm (Fig.10A). Insert the
suction unit inside the structure paying attention that the
previously unscrewed screws O, hook into the slots in the
lower part as indicated in (Fig.10B). Drive in the 3 screws N
(supplied) and tighten the 2 screws O (Fig.10B).
-Fix the air evacuation pipe H (not supplied) onto the
connection ange F (Fig.11).
-Remove adhesive tape L and rest the lower chimney piece
above the cooker hood (Fig.12).
-If necessary, x the lower duct to the hood from the inside,
using the screws P (Fig.13).
USE AND MAINTENANCE
We recommend that the cooker hood is switched on before
any food is cooked.We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The eective performance of the cooker hood depends on
constant maintenance; the anti-grease lter and the active
carbon lter both require special attention.
The anti-grease filter is responsible retaining the grease
particles suspended in the air, therefore it is subject to
clogging with variable frequency according to the use of the
appliance.
- To prevent the danger of possible res, at least every 2
months one must wash the anti-grease lters by hand using
non-abrasive neutral liquid detergents or in the dishwasher
at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This does
not give the right to claim their replacement.
The active carbon filters are used to purify the air that is
sent back into the room and its function s to mitigate the
unpleasant odours produced by cooking.
- The non-regenerable active carbon lters must be replaced
at least every 4 months. The saturation of the active charcoal
depends on the more or less prolonged use of the appliance,
on the type of kitchen and on the frequency with which anti-
grease lter is cleaned.
- Regenerable activecharcoal ltersmust be washed by hand,
with non abrasive neutral detergents, or in the dishwasher at
a maximum temperature of 65°C (the washing cycle must be
complete without dishware). Remove excess water without
damaging the lter, remove the plastic parts, and let the mat
dry in the oven for at least 15 minutes approximately at a
maximum temperature of 100°C. To keep the regenerable
charcoal lter functioning ecient this operation must be
repeated every 2 months. These must be replaced at least
every 3 years or when the mat is damaged.
Before remounting the anti-grease filters and the rege-
nerableactivecharcoal lters it isimportant that they are
completely dry.
Clean the hood frequently, both internally and externally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
The lighting .system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system signicantly decreases
the average duration of the bulbs.
Attention: The non compliance with the hood cleaning
warnings and with the replacement and cleaning of thelters
entailsrisk of res.One therefore recommendskeeping to the
suggested instructions.
Replacing halogen light bulbs (Fig.18):
To replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: Do not touch the light bulb with bare hands.
Commands (Fig.19):
The key symbols are explained below:
A = LIGHT
B = OFF
C = SPEED I
D= SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
If your appliance does not have the INTENSIVE speed
function, press key E for two seconds and it will be activated
for 10 minutes after which it will return to the previously set
speed.Whenthe function is activethe LED ashes.To interrupt
it before the 10 minutes have expired press key E again.
Clean Air:
By pressing key Ffortwoseconds (with thehoodswitched o)
the “clean air function is activated. This function switches
the appliance on for ten minutes every hour at the rst speed.
As soonas this function is activated themotor starts up at the
rst speed for ten minutes. During this time key F and key
C must ash at the same time. After ten minutes the motor
switches o and the LED of key F remains switched on with
a xed light until the motor starts up again at the rst speed
after fty minutes and keys F and C start to ash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key Dis pressed the clean air” function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*) The AUTOMATIC STOP TIMER” delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
Anti-grease and active carbon filters saturation:
-After 30 hours of work, the key A ashes every 2 sec.; in that
event,theanti-greaseand activecarbonltermustbecleaned,
if present.
-After 120 hours of work, the key A ashes every 0.5 sec.; in
thatevent,the standard active carbonltersmustbe replaced,
if present.
- 19 -
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für V-Zug DI-SL10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info