Notes on the documentation 2
0020147164_04 aroTHERM Installation instructions 7
2 Notes on the documentation
2.1 Observing other applicable documents
You must observe all the operating and installation in-
structions included with the system components.
2.2 Storing documents
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3 Applicability of the instructions
These instructions apply to units with the following type des-
ignations and article numbers only:
Type designation Art. no.
aroTHERM VWL 55/2 A 230 V 0010014566
aroTHERM VWL 85/2 A 230 V 0010011971
aroTHERM VWL 115/2 A 230 V 0010011972
aroTHERM VWL 155/2 A 230 V 0010014567
The seventh to sixteenth digits of the serial number on the
identification plate form the article number.
3 System overview
3.1 Safety devices
The product can work at the following outside temperat-
ures:
VWL 55/2 A 230 V VWL 85/2 A 230 V
VWL 115/2 A 230 V
VWL 155/2 A 230 V
Heating mode 15 … 28 20 … 28
Cylinder charging
mode
15 … 46 20 … 46
If the product's coolant circuit pressure exceeds the max-
imum pressure of 4.15 MPa (41.5 bar), the high-pres-
sure pressure switch switches the product off. Follow-
ing a waiting period, the product attempts to start once
more. After three failed start attempts in succession, a
fault message is displayed.
If the product is switched off, the crankcase housing
heating is switched on when the compressor outlet tem-
perature reaches 7 °C in order to prevent possible dam-
age caused by switching it back on.
If the compressor inlet temperature and the compressor
outlet temperature are below 1 °C, the compressor does
not start up.
A temperature sensor on the compressor outlet limits the
product's operation if the measured temperature exceeds
the maximum permissible temperature. The maximum
permissible temperature depends on the evaporation and
condensation temperature.
The product measures the flow rate of the connected
heating circuit when starting up the product.
If the heating circuit temperature falls below 3 °C, the
product's frost protection function is automatically ac-
tivated as the heating pump is started. In addition, frost
protection agent should be added to the heating water as
the heating water temperature may fall below the freez-
ing point in the event of a power cut, which poses a risk
of frost to the heating installation.
Note
Operating the heat pump outside the application
limits results in the heat pump being switched off
by the internal control and safety devices.
3.2 Design of the heat pump system
The heat pump system consists of the following components:
aroTHERM heat pump
VWZ AI heat pump control module
Additional hydraulic components, if required
VRC 470 system controller
The heat pump can be operated by the VWZ AI heat pump
control module. The extended operation of the heat pump is
carried out by the system controller.
3.3 Functionality
The product comprises the following circuits:
The coolant circuit releases heat into the heating circuit
by means of evaporation, compression, condensation
and expansion
The heating circuit
3.3.1 Heating mode
1
2
3
4
5
6
1 Evaporator
2 4-way valve
3 Fan
4 Compressor
5 Electronic expansion valve
6 Plate heat exchanger
3.3.2 Thawing
1
2
3
4
5
6
1 Evaporator 2 4-way valve
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

vaillant-arotherm-vwl-155-2

Suche zurücksetzen

  • Wie viele Tage dauert das Ausheizprogramm bei Vaillant aroTHERM VWL 155-2 Eingereicht am 5-6-2017 18:34

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vaillant aroTHERM VWL 155-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Vaillant aroTHERM VWL 155-2

Vaillant aroTHERM VWL 155-2 Bedienungsanleitung - Deutsch - 24 seiten

Vaillant aroTHERM VWL 155-2 Bedienungsanleitung - Holländisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info