Installation
Installation instructions VRC 470f 0020124645_00 9
4
4 Installation
You can either integrate the radio receiver unit in the
boiler or install it separately on a wall. If you are wall-
mounting the radio receiver unit, you connect it to the
boiler via a 2-core eBUS cable.
You can fix the controller to a wall in the living area.
4.1 Checking the delivery
Quantity Component
1 VRC 470f controller
1 Radio receiver unit
1 VR 21 outside temperature sensor/transmitter
1 Wall-mounting base for radio receiver unit
1 Wall-mounting base for VRC 470f
2 Fastening material (2 screws and 2 wall plugs)
1 Battery set (4 x AA)
1 3-pin pin header connector
1 Operating instructions
1 Installation instructions
Tab. 4.1 Scope of delivery
4.2 Requirements for the installation site
4.2.1 Radio receiver unit
> Install the radio receiver unit in the boiler.
> If radio communication cannot be established when
the radio receiver unit is installed in the boiler, then
install it in a suitable position on a wall.
4.2.2 Controller
> Position the controller so that proper detection of the
room temperature is possible; e.g. on an internal wall
of the main living room, at a height of approx. 1.5 m
> If room temperature control is activated, advise the
operator that, in the room where the controller is
mounted, all the radiator valves must be fully open.
4.2.3 Outside temperature sensor/transmitter
The installation site of the outside temperature sensor/
transmitter should be:
not fully protected from wind
not particularly draughty
not in direct sunlight
not affected by heat sources
on a north or north-west facing wall
easily accessible so that the solar cell can easily be
cleaned
a short distance from the radio receiver unit
> During start-up, check whether radio communication
between the outside temperature sensor/transmitter
and the radio receiver unit can be established.
> If radio communication is adversely affected by elec-
trical equipment or buildings, then choose a different
installation site for the outside temperature sensor/
transmitter.
4.3 Fitting the radio receiver unit in the boiler
e
Danger!
Risk of death from live connections!
When working in the control cabinet of the
boiler there is a risk of death from electric
shock. Continuous voltage is present on the
mains connection terminals, even if the main
switch is turned off!
> Switch the main switch off before working
on the control cabinet of the boiler.
> Disconnect the boiler from the mains
power by disconnecting the mains plug or
by de-energising the boiler via an isolating
device with a contact opening of at least
3mm (e. g. fuses or power switches).
> Secure the power supply against being
switched on again.
> Open the control cabinet only when the
appliance is disconnected from the power
source.
i
When fitting the radio receiver unit in the
boiler's switch box, follow the instructions for
fitting a controller given in the boiler installa-
tion instructions.
Install the radio receiver unit in the boiler as follows:
> Switch off the boiler.
> Ensure that the boiler is disconnected from the power
source.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vaillant VRC 470F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info