0020237057_00 Installation instructions 39
D.2 Troubleshooting
Symptom Possible cause Measure
Display remains dark The batteries are flat Change all the batteries ( Operating instructions, "Changing
the batteries").
The batteries in the control
have not been inserted correctly
Insert the batteries in the battery compartment, making sure
that the poles are the right way round.
The product is defective Replace the product.
No changes in the display when
the rotary knob is turned
Software error 1. Take all the batteries out.
2. Insert the batteries in the battery compartment, making sure
that the poles are the right way round.
The product is defective Replace the product.
No changes in the display
via the selection buttons are
pressed
Software error 1. Take all the batteries out.
2. Insert the batteries in the battery compartment, making sure
that the poles are the right way round.
The product is defective Replace the product.
Heat generator continues to
heat once the room temperature
has been reached
Incorrect value in the Room
temp. mod. or Zone assign-
ment function
1. Set Thermost. or Temp. mod. in the Room temp. mod.
function.
2. In the zone in which the controller is installed, assign the
controller's address in Zone assignment.
The reception strength is too
weak
If the reception strength is 4, find a new installation site for
the control.
System remains in hot water
handling mode
Heat generator cannot reach
the max. target flow temperat-
ure
Reduce the set value in the Max.DHW fl.targ.temp. function.
Only one of several heating
circuits is displayed
Heating circuits inactive Activate the required heating circuit by setting the functionality
in the Type of circuit function.
Only one of several zones is
displayed
Heating circuits inactive Activate the required heating circuit by setting the functionality
in the Type of circuit function.
Zone deactivated Activate the required zone by setting the value to Yes in the
Zone activated function.
Display view: Clean outside
temperature sensor
The battery in the outdoor tem-
perature sensor is flat
Clean the solar cell of the outdoor temperature sensor (
Operating instructions, "Cleaning the outdoor temperature
sensor").
The reception strength of the
outdoor temperature sensor is
weak or non-existent
If the reception strength is 4, find a new installation site for
the outdoor temperature sensor.
The product is defective Replace the product.
Display view: No RF commu-
nication
No power supply to the radio
receiver unit
Reconnect the power supply to the radio receiver unit.
The control is outside the radio
reception range
1. Take the control to the radio receiver unit and see if the re-
ception strength increases.
2. If the reception strength is 4, find a new installation site for
the control.
The product is defective Replace the product.
It is not possible to switch to the
installer level
You do not know the code for
the installer level
Reset the control to the factory settings ( Page 12).
39

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

vaillant-vrc-700f-4

Suche zurücksetzen

  • Is there an english version of the operation instructions manual for Vaillant VRC 700/4 multiMATIC>? Eingereicht am 21-9-2017 14:28

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vaillant VRC 700F-4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info