09
MAINTENANCE OF THE BOILER
Tomaintainyoursteamcleaneringoodconditionandtoensureconstantperfor-
mance, we recommend that you periodically clean the boiler once or twice a year
depending on the hardness of the water:
CLEANING INSTRUCTIONS
ATTENTION: Before cleaning the boiler with the supplied de-scaling powder, please
make sure that the boiler is at room temperature, that it has not been used for at
least 8 hours, and that the boiler is disconnected from the power source.
1. Turnthesteamcleanerover.Unscrewandremovethebolt(removethecap
rst)withthetoolprovidedandeliminateallthewaterremainingintheboiler.
LEAVETHEUNITUPSIDEDOWN.
2. Completelydissolvethecontentsofthesinglepackageofde-scalingpowder
in2cups(0.5l)ofwater.
3. Pourthesolutionintotheboiler.(Attention:Donotputthedissolvedsolu-
tionintothewatercontainer).Placetheboltbackon,andturnoveronits
right side.
4. Leavethesolutionintheboilerfor3hourswiththeboltscrewedonandleave
the product on its right side.
5. Remove the bolt, and completely empty the contents of the boiler and rinse
three or four times with water in order to eliminate possible residues of scale.
6. It is a good idea to spray the first steam onto a cloth and not directly on any
surface since there still may be scale in the system.
ATTENTION: IT IS NOT RECOMMENDED THAT YOU USE ANY OTHER CHEMICAL TO
CLEAN THIS PRODUCT. DOING SO WILL AUTOMATICALLY VOID THE WARRANTY.
ATTACHMENT COUPLINGS
If the attachment connections dry up after intensive use, put a small amount of
lubricant(Vaseline)aroundtheO-ringsonthemaleattachment.
TECHNICAL DESCRIPTION
120V Power 1400W
Coldwatertankcapacity 2L
Workingpressure 4bar
Safety valve Yes