813299
6
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
1. Flue or Chimney
1.1 The flue or chimney system must be in good condition.
It must be inspected by a competent person and passed for
use with the appliance before installation.
Products of combustion entering the room can cause
serious health risks.
1.2 The following must be checked:
The construction of the masonry chimneys, flue block
chimneys and connecting flue pipe system must meet
the requirements of the Building Regulations.
A flexible flue liner system can be used if certified for
use with solid fuel systems and installation complies with
manufacturersinstructionsandBuildingRegulations.
The flue liner must be replaced when an appliance is
replaced, unless proven to be recently installed and in
good condition.
If it is necessary to fit a register plate it must conform
to the Building Regulations.
The minimum height of the flue or chimney must
be 4.5m from the hearth to the top of the flue, with
no horizontal sections and a maximum of 4 bends.
Bends must have angles of less than 45 degrees from
the vertical.
Ensure the connecting flue pipe is kept a suitable
distance from any combustible material and does not
form part of the supporting structure of the building.
Make provision to remove the appliance without the
need to dismantle the chimney.
Installation Instructions
The flue/chimney system should not be supported by
the appliance.
Any existing flue must be confirmed as suitable for
the new intended use as defined in the Building
Regulations.
The flue or chimney systems must be inspected and
swept to confirm the system is structurally sound and
free from obstructions**.
If the chimney is believed to have previously
served an open fire it must be swept a second time
within a month of regular use after installation to clear
any soot falls that may have occurred due to
difference in combustion levels.
The flue exit from the building must comply with local
building control rules.
Do not connect or share the flue or chimney system
with another heating appliance.
1.3 Do not connect to systems containing large voids or spaces
over 230mm square.
1.4 Suitable access must be provided to enable the collection
and removal of debris.
1.5 The flue must be swept and inspected when the appliance is
installed.
Flue Draught
The flue draught must be checked with all windows and
doors closed and any extraction fans in this, or adjoining
rooms, running at maximum speed (see Installation
Checklist for ventilation requirements).
4.5
Flue Outlet Size
(Top or Rear Option)All
mm 128 153
inch 5 6
Flue/Chimney Size
May be reduced to 128mm (5") if burning approved
smokeless fuels or burning wood in an appliance
approved for use in a DEFRA smoke control area
Without flue liner Round (Diameter) mm 153 153
inch 66
Without flue liner system (Square) mm 135 135
inch 51/251/2
With Liner of Factory made system (diameter)
installed in accordance with manufacturers instructions
mm 153 153
inch 66
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth to the top of the flue, with no horizontal sections
and a maximum of 4 bends. Bends must have angles of less than 45 degrees from
the vertical.
m 4.5 4.5
feet 15 15
Flue Draught
Min
mm Wg
1.0 1.0
Nominal 1.25 1.25
Max 2.0 2.0
European Min Spec for Chimney Flue - T400 N2 D 3 G50
NOTE: FLUE/CHIMNEY MUST NOT BE SMALLER THAN THE FLUE OUTLET SIZE
This table gives an overview of the flue and chimney options:
6
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Varde Aura 1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Varde Aura 1

Varde Aura 1 Bedienungsanleitung - Englisch - 12 seiten

Varde Aura 1 Bedienungsanleitung und Installationsanweisung - Englisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info