Technical data, Aura 2
Height (cm) 100
Width (cm) 50
Depth (cm) 45
Weight (kg) 104
Output 3-7 kW
Nominal output 5.0 KW
Heated area 30-105 m2
Efficiency 81%
EEI 108
Flue gas data: 265°C at 25°C, 12 pa.
Combustion chamber: (H x W x D):
24.5-36.0x30.0x28.0 cm
Smoke outlet Ø 15 cm
Installation height, top: 97 cm
Installation height, rear: 83 cm
Distance to non-flammable material:
5–10 cm (recommended)
Distance to flammable material:
Rear=12.5 cm, Side=30 cm, Front=30 cm
21
How to correct a fault.
Smoke entering room
• Poor draught in the chimney.
• Check that the flue and chimney are not blocked.
• Check that the chimney height is correct in accordance with the surroundings.
Glass and/or chimney soot:
• Wood is too wet.
• There is insufficient combustion air (secondary air).
• You have closed the kindling air too quickly when you started the fire.
• There must always be clear flames in the combustion chamber.
The stove is not heating the room:
• The wood is too wet (all the energy is being used up in drying the wood) or the wood is
poor quality.
• Check that the smoke guide plate is positioned correctly (free passage for smoke).
• Insufficient combustion air (secondary air).
The fire burns too intensely:
• The gasket in the door or ash pan does not seal (it must be replaced).
• The chimney draught is too powerful (fit a damper in the chimney).
• Check that the kindling air is closed.
The shaker grate is stuck:
• Check that a piece of wood or similar is not stuck in the grate.
• Check that the shaker grate bar is in the correct position.
Recycling
Packaging
In consideration of the environment, the packaging should be disposed of in accordance with
local regulations for the disposal of waste. The packaging is 100% recyclable.
Ceramic glass
Ceramic glass must be taken to the local recycling station and recycled with other ceramics
and porcelain, where it is sent to a waste disposal facility.
Vermiculite
Vermiculite panels from the stove must be taken to the recycling station, where they will be
sent to a waste disposal facility