813303
4
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
4
If the fire subsides re-open the combustion air
control to re-establish the flames.
Experience establishes settings to suit personal
preferences.
Do not burn large amounts of fuel with the combustion
air control closed for long periods of time. This reduces
the glass cleaning effect and causes tars and creosotes
to build-up in the appliance and flue system and will
produce excessive amounts of smoke.
When in use, burning the appliance at high output for a
short period also reduces tars and creosote.
When running the appliance:
Refuel little and often for clean, efficient burning.
Wood burns best on a bed of ash.
A bright and clean firebox indicates the appliance is
burning well.
5. Controlling the air
The appliance has various features for the air control:
Primary air control
The valve on the ash-pan is for use initially when lighting
fires.
- Burning position: The control is closed when the small
handles are in the horizontal position.
- Lighting position: The control is open when the small
handles are in the vertical position, allowing a flow of
primary air into the combustion chamber.
Combustion/ Secondary air
Pre-heated air for the combustion process which, can be
altered according to the desired room temperature and
the effectiveness of the chimney.
A high level of chimney draught requires a smaller intake
of combustion air.
Tertiary air (Pre-set)
Constantly added air, which makes the appliance burn
cleaner and lowers the content of tar and soot in the
combustion process to an absolute minimum.
At optimal combustion settings, the glass and
combustion chamber will be burnt completely clean and
the remaining amount of ashes will be minimal.
5. Advice
Never burn wood with an open door.
If you frequently have low intensity fires, tar and creosote
may be deposited in the chimney. Tar and creosote are
highly combustible substances. Thicker layers of these
substances might catch fire when the temperature in the
chimney increases suddenly and steeply. Therefore it is
necessary for the fire to regularly burn at a high output for
short periods, so that layers of tar and creosote
disappear.
Low intensity fires also cause tar deposits on the
appliance window and door.
When the outside temperature is not very low, it is better
to burn wood intensely for a few hours instead of having
a low intensity fire for a long period of time.
Control the air supply with the combustion air control.
The combustion air inlet not only supplies airwash to
the fire but to the glass as well, so that it does not get
dirty so quickly.
Open the primary air inlet for a time if the air supply by
the secondary air inlet is inadequate or if you want to
boost the fire, for a short period.
Do not use the appliance continuously with the
air controls fully open.
It is better to add a small amount of logs regularly than to
add many logs at the same time.
6. Extinguishing the fire
Do not add fuel and just let the fire go out. If a fire is
damped down by reducing the supply of air, harmful
substances will be produced and released. Therefore, let
the fire go out naturally. Keep an eye on the fire until it is
gone out. If the fire has died completely, all air inlets can
be closed.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Varde Aura Smoke Control Kit wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info