For measurements up to 600mA: connect the red test lead to the "µAmA" jack
and the black lead to the "COM" jack.
For measurements up to 10A: connect the red test lead to the "10A" jack and
the black lead to the "COM" jack.
Set the rotary switch to the µA range for measurements up to 600µA (only when
test probe is connected to the µAmA jack).
Set the rotary switch to the mA range for measurements up to 600mA (only when
test probe is connected to the µAmA jack).
Set the rotary switch to the A range for measurements up to 10A (only when test
probe is connected to the 10A jack).
Press the SELECT button to select DC current (DCA) or AC current (ACA) mode.
Connect the test probes in series with the circuit.
Read the measured value from the display.
Notes:
o for DC-current measurements, when a negative polarity is present at the red
test lead, the indicated value is preceded by a “-” sign.
o The µAmA-range is protected against over current with a F630mA 1000V fuse,
the 10A-range is protected against over current with a F10A 1000V fuse.
8. Maintenance
Do not replace internal parts yourself. Replace damaged or lost accessories
by identical ones with the same specifications. Order spare accessories e.g.
test probes at your dealer.
a. General maintenance
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or
solvents.
b. Fuse Replacement
Switch off the multi-meter, disconnect the test leads from the test points
and remove the test leads from the measuring jacks before replacing the
batteries or fuses.
Refer to the illustration on pages 3 of this manual.
Remove the 4 screws at the back (indicated with in the illustration) and gently
open the meter.
Remove the screw that holds the PCB in place (indicated with in the
illustration) and gently lift the PCB.
Remove the fuse from the fuse holder and replace it with a new fuse of the same
type and with the same specifications (F630mA/1000V - Ø10.3x38mm,
F10A/1000V - Ø10.3x38mm).
Close the meter meticoulsly.
c. Battery Replacement
To avoid false readings, which could lead to possible electric
shocks or personal injury, replace the battery as soon as the
battery indicator appears.
Switch off the multi-meter, disconnect the test leads from the test
points and remove the test leads from the measuring jacks before
replacing the batteries or fuses.
Refer to the illustration on pages 3 of this manual.
Remove the 2 screws at the back of the meter (indicated with in the
illustration) and gently open the battery compartment.
Replace the battery (9V 6LF22). Do not use rechargeable batteries. Insert
following the right polarity.
Close the battery compartment and reseat the screws.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Velleman DVM4100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info