333-90-30007467Vermont Castings • Stardance SDDVT Installation Manual_R35 • 11/23
A. Massachusetts Safety Information
The Stardance Direct Vent Room Heater, Model Nos. SDDVT-
IFT-BD, SDDVT-IFT-BM, SDDVT-IFT-BS, SDDVT-IFT-CB,
SDDVTBSB, SDDVTBSSB, SDDVTBDSB, SDDVTBMSB, is
a vented gas appliance listed to the ANSI Standard Z21.88-
2019 and CSA 2.33-2019 for Vented Room Heaters, and
CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Stardance Direct Vent Room Heater must
conform with local codes, or in the absence of local codes, with
National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition
and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate
this appliance for altitude. Maintain the manifold pressure at 3.5
inches w.c. for Natural Gas and 10 inches w.c. for LP gas at
maximum input.)
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases unless a certied kit is used.
Installation and replacement of gas piping, gas utilization
equipment or accessories, and repair and servicing of
equipment shall be performed only by a qualied agency,
preferablyNFIorWETT(Canada)certied.Theterm“qualied
agency”meansanyindividual,rm,corporation,orcompany
that either in person or through a representative is engaged
inandisresponsiblefor(a)installationorreplacementofgas
piping,or(b),theconnection,installation,repair,orservicing
of equipment, who is experienced in such work, familiar
with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
TheStardanceDirectVentRoomHeatershouldbeinspected
beforeuseandatleastannuallybyaqualiedserviceagency.
It is imperative that control compartments, burners, and
circulatingairpassagewaysoftheappliancebekeptclean.
The Stardance Direct Vent Room Heater and its individual shut-o󰀨
valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2
psig (3.5 kPa).
The Stardance Direct Vent Room Heater must be isolated from the
gas supply piping system by closing its individual manual shuto󰀨
valve during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig.
An accessible tap is located above the pilot/On-O󰀨 knob for checking
the inlet pressure.
‘Direct Vent’ describes a sealed combustion system in which
incoming outside air for combustion and outgoing exhaust enter
and exit through two separate concentric passages within the same
sealed vent system. The system does not use room air to support
combustion. The Direct Vent system permits the gas appliance to
be vented directly to the outside atmosphere through the side of the
house or vertically through the roof. Conventional venting systems
(Natural Vent) take air from the room for combustion and vent the
exhaust vertically through the roof to the atmosphere.
This appliance is approved for bedroom installations in the U.S.
and Canada.
This appliance may be installed in an aftermarket* manufactured
(mobile) home, where not prohibited by state or local codes.
WARNING: Operation of this heater when not connected to a
properly installed and maintained venting system can result in
carbonmonoxide(CO)poisoningandpossibledeath.
The Stardance Direct Vent Room Heater, when installed, must
be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code ANSI/NFPA
70, (latest edition), or of the current Canadian Electrical Code C22.1.
Duetohightemperaturesthisapplianceshouldbelocatedout
oftra󰀩candawayfromfurnitureanddraperies.
WARNING: This appliance is hot while in operation. Keep
children, clothing, and furniture away. Contact may cause
burnsorignitionofcombustiblematerials.
Childrenandadultsshouldbealertedtothehazardsofhigh
surfacetemperaturesandshouldstayawaytoavoidburnsor
clothing ignition.
Youngchildrenshouldbecarefullysupervisedwhentheyare
in the same room as the appliance. Toddlers, young children
andothersmaybesusceptibletoaccidentalcontactburns.A
physicalbarrierisrecommendedifthereareatriskindividuals
in the house. To restrict access to a stove or stove, install an
adjustablesafety gatetokeeptoddlers,youngchildrenand
other at risk individuals out of the room and away from hot
surfaces.
A barrier is designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
Ifthebarrierbecomesdamaged,thebarriershallbereplaced
withthemanufacturersbarrierforthisappliance.
Clothingorotherammablematerialsshouldnotbeplaced
on or near the appliance.
Any safety screen, glass or guard removed for servicing an
appliancemustbereplacedpriortooperatingtheappliance.
Theapplianceareamustbekeptclearandfreefromcombustible
materials,gasoline,andotherammablevaporsandliquids.
The flow of combustion and ventilation air must not be
obstructed.Theinstallationmustincludeadequateaccessibility
and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass panel
removed,crackedorbroken.Replacementofthepanelshould
bedonebyalicensedorqualiedserviceperson.
Donotusethisapplianceifanyparthasbeenunderwater.
Immediatelycallaqualiedservicetechniciantoinspectthe
appliance and to replace any part of the control system and
anygascontrolwhichhasbeenunderwater.
Donotburnwood,trashoranyothermaterialforwhichthis
appliance was not designed. This appliance is designed to
burneithernaturalgasorpropaneonly.
Thisgasappliancemustnotbeconnectedtoachimneyue
servingaseparatesolid-fuelburningappliance.
CAUTION:Labelallwirespriortodisconnectionwhenservicing
controls. Wiring errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
* Aftermarket: Completion of sale, nor for purpose of resale, from
the manufacturer.
1 1 Important Safety Information
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vermont Castings Stardance Series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Vermont Castings Stardance Series

Vermont Castings Stardance Series Bedienungsanleitung - Französisch - 54 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info