5. Configuration
5.1. Menu structure and configurable parameters
After completing the installation and setting up the internet connection (if required), go through the menu from top to bottom to
configure the Cerbo GX:
Item Default Description
General
Access level User and installer Set this to 'User' to prevent accidental and unwanted changes to the configuration.
Remote support Off Enable this to allow Victron engineers to access your system in case there is a problem.
Reboot? Reboots the GX device
Audible alarm On When there is an alarm on the Cerbo GX or a connected product, the Cerbo GX will beep - unless
this setting is set to 'Off'.
Demo mode Off Turn 'On' to demonstrate product and installation features to a client or at an exhibition. This sim-
ulation mode will allow better understanding without (yet) changing any settings.
Firmware
Firmware Version x.xx Displays the currently installed firmware version
Online updates: Auto update Check only If this is Enabled, the GX device will check with the server to see if there is a new version availa-
ble. It is possible to set to disable, or update automatically
Online updates: Update to Latest release Use the default setting unless you want to participate in test versions. End-user systems should
certainly be set to 'Latest release'.
Install firmware from SD/USB Use this menu to install a new version from a microSD card or USB stick. Insert the card or stick
that holds the new firmware .swu file.
Stored backup firmware With this feature you can go back to the previously installed firmware version.
Date & time
Date/Time local Automatic from internet When connected to the internet, time will be automatically synchronised regardless of this setting.
Toggle the setting Manually input the time where no internet connection is present.
Change time zone Select the correct time zone.
Remote console
Disable password check Password authentication not required for remote console access.
Enable password check Choose password to allow remote console access.
Enable on VRM No Enabling on VRM will allow connection to the Cerbo GX from anywhere via the VRM portal. Trou-
ble shooting Remote Console on VRM
Enable on LAN No Enabling will allow direct connection to the Cerbo GX by typing its IP address or Venus.local into
a web browser, or in VictronConnect when connected to the same network. Only Enable this func-
tion on trusted networks. Disable password check, or set password first
System setup
AC input 1 Generator Select Generator or Grid. (We will shortly be adding the setting 'Shore power' instead of grid.)
AC input 2 Grid Same choices as above.
Monitor for grid failure Disabled Monitors for loss of AC-input, and triggers an Alarm if detected. Alarm is cleared when the AC-
input is reconnected.
Battery monitor Automatic Select the SOC source. This function is useful where there is more than one BMV. More details.
Has DC system No Enable this for boats, vehicles and installations with DC loads and chargers - in addition to Multi
and MPPT chargers. This won't be applicable to most off-grid installations; and any discrepancy
between the DC current measured by the Multi, and by the BMV, will be attributed to a 'DC sys-
tem'. This may be power-in from an alternator, or power-out from a pump, for example.
A positive value indicates consumption. A negative value indicates charging, for example by an
alternator.
Note that the value shown will always be an approximation, and is affected by the variation in
sample rate between elements of the system.
Marine MFD App Configuration Not set Set up what batteries you want to see on the MFD, and by what name.
DVCC
DVCC No
Limit Charge Current No
SVS - Shared voltage sense
STS - Shared temperasure sense
Temperature sensor
SCS - Shared current sense
Display & language
Brightness Configure the brightness between 0 and 100%
Display off time Set time-to-off between 10s / 30s - 1m / 10m /30m - or never
Cerbo GX Manual
26
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron Cebro GX wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info