785503
9
Zoom out
Zoom in
Vorherige Seite
1/75
Nächste Seite
9
EN NL FR DE ES Appendix
3.1. Rotary switch
The rotary switch provides the user with a selection of preset battery types to be charged. See table below.
Warning: the charge voltages as given below are indicative only. Always refer to the battery supplier for the right
charge voltages.
Pos
Description
Absorption
Float
Storage
Equalization
dV/dT
V
V
V
maxV@% of Inom
mV/°C
0
Do not use
1
Gel Victron long life (OPzV)
Gel exide A600 (OPzV)
Gel MK
28,2 27,6 26,4 31,8@8% max 1hr -32
2
Default setting
Gel Victron deep discharge, Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (flooded), Rolls Solar (flooded)
28,8 27,6 26,4 32,4@8% max 1hr -32
3
AGM spiral cell
Rolls AGM
29,4 27,6 26,4 33,0@8% max 1hr -32
4
PzS tubular plate traction batteries or
OPzS batteries in cyclic mode 1
28,2 27,6 26,4 31,8@25% max 4hrs -32
5
PzS tubular plate traction batteries or
OPzS batteries in cyclic mode 2
28,8 27,6 26,4 32,4@25% max 4hrs -32
6
PzS tubular plate traction batteries or
OPzS batteries in cyclic mode 3
30,0 27,6 26,4 33,6@25% max 4hrs -32
7
Lithium Iron Phosphate (LiFePo4) batteries
28,4
n. a.
26,7
n. a.
0
8
Adjustable: maximum charge current and
absorption and float voltages can be set with
potentiometers
Adj. Adj. 26,4
(Vabs. + 3,6V)@25%
max 4hrs
Veq-max < 33.6 V
-32
9
Power supply mode
24,0
n. a.
n. a.
n. a.
0
3.2. DIP switch
The DIP switches are numbered 6 to 1, top to bottom.
Default settings:
DS-6 Bulk Protection
on
DS-5 Absorption time
off
DS-4 Absorption time
on
DS-3 Adaptive
on
DS-2 Watch
on
DS-1 Automatic equalization
off
3.3. Explanation of settings:
DS-6. Bulk Protection. When switched on, the failure LED will be lit and the charger will shut down when the bulk time exceeds
10 hrs.
DS-5 and DS-4. Absorption time. The combination of switches 5 and 4 sets the maximum absorption time in case of adaptive
charging, and a fixed time in case the adaptive mode has been switched off (DS-3).
DS-5
DS-4
Absorption time
Off
Off
2 hrs (preferred for LiFePo4 batteries)
On
Off
4 hrs.
Off
On
8 hrs. (default)
On
On
12 hrs.
DS 3. Adaptive. When switched on, the absorption and float time depend on the bulk time (with the maximum time set by DS-5
and DS-4).
The dependencies are as follows:
Absorption time = (bulk time)*20 with a minimum of 30 minutes and a maximum as set by DS-5 and DS-4.
Float time = (bulk time)*20 with a minimum of 4hrs and a maximum of 8hrs.
DS-2. Watch. When DS-2 is on, the battery voltage is checked when the charger is switched on. If the voltage exceeds 26V, the
charger will consider the battery fully charged, and start in storage mode. If the voltage is lower, the charger will start in bulk
mode.
When DS-2 is off, the charger will always start in bulk mode.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron Skylla-i 24 80 (1 1) wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info