5. FAULT TRACING
When a fault occurs in the battery charger, the following table can be used in order
to find the fault. Before the Skylla is being checked, make sure that all the devices
connected to the battery charger are removed. If the fault can not be solved, please
contact your Victron Energy dealer.
Problem
Possible cause
Solution
The charger does
not operate
The mains voltage has to be in
between 90Vac and 265 Vac.
Measure the mains voltage and make sure
it is in between 90Vac and 265Vac.
A broken input fuse.
Return the charger to your dealer.
The battery is not
being fully charged
The equalize-charge mode is set to
a too short period.
Set the equalize-charge mode to a longer
time.
A bad battery connection.
Check the battery connections.
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the
right value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to the right
value.
The capacity of the battery is too
large.
Connect a battery with a smaller capacity
or install a larger charger.
The output fuses are broken.
Replace the output fuses.
The battery is
being overcharged
The battery charger is set into the
permanent boost-charge mode.
Deselect the permanent boost DIP-switch
(Rboost).
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the
right value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to right
value.
A bad battery.
Check the battery.
The battery is located in a warm
place
Connect a temperature sensor
The battery is too small.
Reduce the charge current.
The failure led
illuminates
The charger is switched off as a
result of a high ambient
temperature.
Place the charger in a cooler, or better
ventilated place.
The failure led
flashes
The charger is reducing the output
current as a result of a high
ambient temperature.
Place the charger in a cooler, or better
ventilated place.
The failure led
flashes in a code
1
The output fuses are broken.
Replace the output fuses.
The failure led
illuminates in
combination with a
blinking on/off led
There is a voltage drop higher than
2V across the battery cables.
Turn the charger off, replace battery cables
and connect them well.
1
Flashing code sequence is two times on in one second and then one second off.
A qualified technician may only remove the cover of the Skylla.
Before obtaining access to the Skylla the mains supply circuit
must be disconnected.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron Skylla-TG 24 50 (1 1) wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info