813784
54
Zoom out
Zoom in
Vorherige Seite
1/72
Nächste Seite
54
Clean the surface of the programming unit with a
microfibre cloth.
!Please note
Commercially available domestic cleaning
agents and special cleaning agents for the heat
exchanger (evaporator) can damage the indoor
and outdoor units.
Clean the appliance surfaces only with a damp
cloth.
If necessary, clean the heat exchanger (evap-
orator) fins on the back of the outdoor unit only
with a hand brush with long bristles.
Danger
The sharp edges of the heat exchanger (evapo-
rator) fins can cause cut injuries.
Do not touch the fins on the back of the outdoor
unit.
Danger
The hot or cold fins of the heat exchanger
(evaporator) can cause burn or frostbite injuries.
Do not touch the fins on the back of the outdoor
unit.
!Please note
Commercially available cleaning agents can
damage the surface of the external casing.
Use only mild water-based domestic cleaning
agents.
Do not use substances containing acids or
solvents, such as vinegar-based cleaners,
nitro or synthetic resin solutions, nail varnish
remover, ethyl alcohol, etc.
!Please note
Mechanical impact will scratch the surface of the
external casing.
Wipe the surface with a soft damp cloth only.
Do not use substances that contain abrasive
particles such as polishes, scouring agents,
dirt erasers or scouring pads.
Do not clean the external casing with a pres-
sure washer.
Inspection and maintenance
The inspection and maintenance of a heating system
is prescribed by the German Buildings Energy Act and
the DIN 4755, DVGW-TRGI 2018, DIN 1988-8 and
EN 806 standards.
Regular maintenance ensures trouble-free, energy effi-
cient, environmentally responsible and secure heating
and cooling operation. For this, it is best to arrange an
inspection and maintenance contract with your local
contractor.
Note
Your outdoor unit contains highly flammable refrigerant
of safety group A3. To ensure operational reliability
over the entire service life of the heat pump, there are
special requirements for inspection and maintenance.
A special test of safety equipment is required after
12 years. Please contact your contractor.
DHW cylinder
Standard EN 806-5 specifies that maintenance and
cleaning should be carried out no later than 2 years
after commissioning and as required thereafter.
Only a qualified contractor should clean the inside of
the DHW cylinder and the DHW connections.
If any water treatment equipment (e.g. a sluice or
injection system) is installed in the cold water supply of
the DHW cylinder, ensure this is refilled in good time.
For this, observe the manufacturer's instructions.
Safety valve (DHW cylinder)
The function of the safety valve must be checked
every six months by the user or a contractor through
venting (see valve manufacturer's instructions). The
valve seat may become contaminated.
Water may drip from the safety valve during a heat-up
process. The outlet is open to the atmosphere.
!Please note
Overpressure can cause damage.
Do not close the safety valve.
Maintenance
Cleaning
6199646
54

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Viessmann VITOCAL 250-A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Viessmann VITOCAL 250-A

Viessmann VITOCAL 250-A Bedienungsanleitung - Deutsch - 80 seiten

Viessmann VITOCAL 250-A Bedienungsanleitung - Holländisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info