Safety
5
For your Safety (continued)
H Carbon monoxide
The U.S. Consumer Product Safety
Commission strongly recommends the
installation of carbon monoxide
detectors in buildings in which
gas-burning equipment is installed.
Carbon monoxide (CO) is a colorless,
odorless gas, which may be produced
during incomplete combustion of fuel
and/or when the flame does not receive
an adequate supply of combustion air.
Carbon monoxide can cause severe
personal injury or loss of life.
Therefore, carbon monoxide detectors
that are in compliance with a nationally
recognized standard (e.g. ANSI/UL
2034-2002, CSA 6.19-01) should be
installed and maintained in buildings that
contain gas-burning equipment.
Note:
Viessmann does not test any detectors
and makes no representation regarding
any brand or type of detector.
H For safe operation
We recommend that you frequently:
- Check for debris which could obstruct
the flow of flue gases. The vent or
chimney must not be blocked. A
blocked or partially blocked vent or
chimney can cause flue gases to leak
into the structure. Flue gases leaking
into the house can cause injury or
death. A qualified heating contractor
must remove the blockage from
blocked or partially blocked chimneys.
- Check pressure gage for correct
system (water) pressure. Check for
water on the floor from the discharge
pipe of the pressure relief valve or any
other pipe, pipe joint, valve or air
vent.
- Check for moisture, water, or
appearance of rust on the flue gas
pipes, their joints as well as vent
dampers, or side wall vent terminals
(if so equipped).
- Ensure that nothing is obstructing the
flow of combustion and ventilation air
and no chemicals, garbage, gasoline,
combustible materials, flammable
vapors and liquids are stored (not
even temporarily) in the vicinity of the
boiler.
-Donot allow unsupervised children
near the boiler.
Service/inspection of the boiler and the
system is recommended once per year.
Maintenance, service and cleaning are
specified in the Installation and Service
Instructions.
Before the heating season begins, it is
recommended that the boiler and burner
be serviced by a qualified heating
contractor. Service contracts may be
established through gas suppliers or
other licensed contractors in your area.
5581 532 v1.1
As there are no user-serviceable parts
on the boiler, burner or control, the
end-user must not perform service
activities or adjustments of any kind on
system components. Failure to heed
this warning can cause property
damage, severe personal injury, or loss
of life.
WARNING
Improper installation, adjustment,
service, or maintenance can cause flue
products to flow into living space. Flue
products contain poisonous carbon
monoxide gas which can cause nausea
or asphyxiation resulting in severe
personal injury or loss of life.
WARNING
Should overheating occur or the gas
supply fail to shut off, do not
disconnect the electrical supply to the
pump. Instead, shut off the gas supply
at a location external to the appliance.
CAUTION
The operator/ultimate owner is required
to have the heating boiler, burners, and
controls checked, as a minimum once
per year, by the original installer or by a
competent heating contractor familiar
with the equipment. Defects must be
corrected immediately.
WARNING
Do not use this boiler if any part has
been under water. Immediately call a
qualified heating contractor to inspect
the boiler and to replace any part of the
control system and any gas control
which has been under water.
CAUTION
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Viessmann Vitodens 100-W WB1A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Viessmann Vitodens 100-W WB1A

Viessmann Vitodens 100-W WB1A Installationsanweisung - Englisch - 104 seiten

Viessmann Vitodens 100-W WB1A Bedienungsanleitung - Holländisch - 20 seiten

Viessmann Vitodens 100-W WB1A Installationsanweisung - Holländisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info