Vitovent 200-W, Vitovent 300-C and Vitovent 300-W:
It is warmer inside than outside.
The room temperature is higher than the "Set room
temperature" for ventilation.
The outdoor air is warmer than 7 °C.
Passive heating
Warmer outdoor air is supplied to the rooms on warm
spring days, for example.
The bypass is active for passive heating if all of the fol-
lowing conditions are met:
Vitovent 200-C and Vitovent 300-F:
The outdoor air is at least 4 °C warmer than the
room temperature.
The room temperature is at least 1 °C cooler than
the "Set room temperature" for ventilation.
Note
With the Vitovent 200-W, Vitovent 300-C and
Vitovent 300-W, passive heating is not possible.
Air flow rates
In order to prevent any negative or positive pressures
developing in your rooms, the flow rate of the supply
air must exactly match the flow rate of the extract air.
Your contractor regulates these air flow rates during
commissioning.
Regulating the humidity and carbon dioxide con-
centration (CO2 concentration)
If a CO2/humidity sensor (accessories) is installed in
one of your rooms, the ventilation unit can adjust the
air flow rate subject to the humidity and/or carbon
dioxide concentration (CO2) of this room.
If a humidity sensor (accessories) is installed in the
central extract air duct, the ventilation unit can adjust
the air flow rate subject to the humidity of all rooms.
The humidity and carbon dioxide concentration can
only be controlled in the "Ventilation program".
Frost protection for the heat exchanger in the ven-
tilation unit
Heat recovery transfers heat from the extract air to the
incoming outdoor air. This causes the extract air to
cool down, which in turn leads to condensate forming
in the heat exchanger. At low outside temperatures,
condensate can freeze on the heat exchanger. Heat
recovery is reduced. The worst-case scenario is that
the ice damages the heat exchanger.
Frost protection with electric preheating coil:
To prevent ice forming on the heat exchanger, the
outdoor air can be preheated by an electric preheat-
ing coil before it enters the heat exchanger. Some
ventilation units have an electric preheating coil pre-
fitted at the factory. For other units, your contractor
will install an electric preheating coil in the outdoor
air duct.
Frost protection without electric preheating coil:
If your ventilation unit does not have an electric pre-
heating coil, the air flow rate will be reduced in order
to protect the heat exchanger, if necessary until the
fans come to a standstill.
Defrost functions: Only with Vitovent 200-C
Your contractor can set various functions to defrost
any ice that may have formed on the heat
exchanger: e.g. the outdoor air flow rate can bypass
the heat exchanger and/or the supply air flow rate
can be reduced. In addition, the electric preheating
coil (accessories) can be switched on.
Note
With frost protection, the indicated ventilation level
may deviate from the ventilation level selected. The
ventilation level displayed is adjusted to reflect the
reduced air flow rate brought about by the frost protec-
tion function.
Only with Vitovent 300-F: supply air heating via
heating circuit 1 (ventilation heating circuit)
If a hydraulic reheating coil (accessories) has been
installed in your ventilation unit, the supply air can be
heated by the heat pump. The outdoor air/supply air
preheated in the heat exchanger of the ventilation unit
is reheated via the hydraulic reheating coil of the heat
pump.
In such a case, set the room temperature and time
program for central heating via the menu for heating
circuit 1.
Note
The level of heating output that can be transmitted via
the ventilation heating circuit is only minimal. Using
supply air heating as the sole heat source is therefore
only recommended for highly insulated buildings (e.g.
passive houses).
Cooling mode
See "Heating mode/cooling mode".
Appendix
Terminology (cont.)
5817913
96

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Viessmann VITOTRONIC 200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Viessmann VITOTRONIC 200

Viessmann VITOTRONIC 200 Bedienungsanleitung - Deutsch - 112 seiten

Viessmann VITOTRONIC 200 Bedienungsanleitung - Holländisch - 112 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info