536360
4
Zoom out
Zoom in
Vorherige Seite
1/29
Nächste Seite
33
a PC connected all the time. The chargers USB interface makes it simple to create a PC connection
and transfer data for subsequent further processing.
The USB port can be used to control the charger from a PC, and it also supplies a means of reading out
the integral data logger. The battery data can then be further processed using the associated PC soft-
ware.
A packs voltage level under load conditions is an important criterion when assessing the quality of cells
and batteries. However, if a pack is to maintain a high voltage under load, it is also vital that its internal
resistance should be as low as possible. To determine the internal resistance of batteries the ALC 8500-
2 Expert features an integral battery Ri measurement circuit.
A further special feature of the ALC 8500-2 Expert is its integral lead-acid battery activator (reviver)
function, whose purpose is to prevent crystalline sulphate deposits on the lead plates. Crystalline sul-
phate deposits are a particular problem with lead-acid batteries which are stored for long periods, are
seldom used, or are only ever discharged at low currents. The useful life of these batteries can be con-
siderably extended by using the activator function.
A summary of the ALC 8500-2 Expert’s most important characteristics and features:
• Four charge channels, for connecting four cells / batteries
• Simultaneous operation on all four channels, even when different functions are selected
• Accurate battery capacity readings; ideal for selecting battery packs
• Charged-in / discharged capacities can be displayed for each battery individually
• Wide range of charge programs for optimum battery care: charge, discharge, discharge /
charge, refresh, cycle, test / capacity measurement, forming (balancing), trickle charge after
main charge
• Support for different battery technologies: NC, NiMH, Lead-Acid, Lead-Gel, Lithium-Ion, Li-
thium-Ion-Polymer
• Lead-acid activator function for elimination of sulphate deposits
• Integral battery Ri measurement circuit
• Integral data logger for recording and storing complete charge / discharge curve proces-
ses
• Data retention if mains supply fails; automatic program start when the mains supply is res-
tored
• USB PC interface for controlling the ALC 8500-2 Expert; also for reading out the data logger
(galvanically isolated)
• Display of cell voltage, charge current, discharge current, charged-in capacity, discharged
capacity
• Integral temperature-controlled cooling fan
• Temperature guard circuits for transformer and output stage
• Future-proof flash technology for firmware updates and upgrades
• Straightforward operation using jog dial and menu control system.
Table 1: performance data of the ALC 8500-2 Expert
Nominal battery capacity, channels 1 and 2 ................................................. 200 mAh to 200 Ah
Nominal battery capacity, channels 3 and 4 ................................................... 40 mAh to 200 Ah
Charge power, channels 1 and 2 ........................................................................max. 40 VA total
Discharge power, channels 1 and 2 .......................................................max. 40 VA per channel
Charge power, channels 3 and 4 ........................................................................max. 15 VA total
Discharge power, channels 3 and 4 .......................................................max. 15 VA per channel
Charge voltage, channels 1 and 2 .................. 30 V (max. 24 V nominal voltage with NC, NiMH)
Charge voltage, channels 3 and 4 .................. 15 V (max. 12 V nominal voltage with NC, NiMH)
Charge current, channels 1 and 2 ........................................................................... 40 mA to 5 A
Charge current, channels 3 and 4 ............................................................................. 8 mA to 1 A
Max. dissipated power of heat-sink assembly ....................................................................90 VA
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

voltcraft-alc-8500-expert

Suche zurücksetzen

  • Bei Ladeschlußspannung automatische abschaltung ja oder nein Eingereicht am 6-4-2018 08:55

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Voltcraft ALC 8500 EXPERT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Voltcraft ALC 8500 EXPERT

Voltcraft ALC 8500 EXPERT Bedienungsanleitung - Deutsch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info