28
InitialOperation
ƽ
Donotexceedthemaximumpermittedinputvalues.
Beforemeasuring,checkthemeasuringdevicefordamagesuchascuts,cracks
orsqueezing.Adefectivedevicemustnotbeused.Mortaldanger!
Beforeusingforthefirsttime,theenclosedbufferbatterybeinsertedforthetimeanddate.Insertingand
changingthebatterycanbefoundinSection„MaintenanceandCleaning“.
After inserting the buffer battery, connect the measuring device in a standard protection socket. The
measuringdeviceisreadyforprogrammingoroperation.
Basicsettings
Afterthefirstuse,someparametersmustbepresettoallowacorrectdisplay.Youcanreachthismodeby
pressingthe„MODE“and„Continue“keys(7)foratleast2secondssimultaneously.Younowreachthe
„SelectdeviceID“menuitem.
a)SelectIDdevice
ThisequipmentIDnumberallowsyou toadminister upto 10electrical userson onemeter unit.In the
adjustmentmodetheIDnumberblinksintherightupperdisplay.Choosethedesiredidentificationnum-
ber(ID0-9withthebuttons“min”(3)and“max”(4)andconfirmyourchoicewiththebutton“MODE”(5).
Themachinewillthensendyouautomaticallytothenextmode,“timesetting.”
b)Timesettings
Firstyouselectthethedesiredtimeformat(12/24-hsystem)withthetwoarrowkeys(3and4)andcon-
firmyourselectionwiththe„MODE“key(5).
Selectthedateformatwiththetwoarrowkeys(3and4).Availableare:
dd.mm.yyyy forday/monthandyearor
mm.dd.yyyy formonth/dayandyear
Confirmtheselectionbypressingthe“MODE“(5)key.Youwillautomaticallyreachthenextmode.
Thehoursdisplayofthetimeflashes.Setthecorrecttimewiththearrowkeys(3and4).Afterentering
thehours,youreachtheminuteinputbypressingthe„Continue“arrowkey(7).Repeatthesestepsuntil
youhavesetday,monthandyear.
Confirmyoursettingsintheyearmodebypressingthe“MODE“(5)key.Thetimestartstorunandyou
automaticallyreachthenextmode.