Each further press takes you to the next higher measuring range
and then starts with the lowest again.
To deactivate the „RANGE“ function again, press the button „RANGE“
(2) anew for 2 seconds or activate the range selection switch (8).
This function is not available in the measuring range diode test and
continuity test.
Low imp. function
Low impedance measuring enables the suppression of phantom
feeds, which may occur in high-Ohm measuring.
As the inner resistance is reduced to approx. 390 kOhm with this mea-
suring operation, which strains the circuit slightly, this function may
only be applied up to max. 250 V and for max. 3 seconds.
This function is only applicable in the voltage measuring range.
Auto-Power OFF:
The automatic cutoff function protects your device from unneces-
sary battery power consumption. In normal operation, the Auto
Power OFF function turns the measuring device off after approx. 15
minutes.
You can „wake up“ the DMM after shutdown via the buttons
„MODE“, „RANGE“, „HOLD“ or by operating the rotary switch.