536155
32
Zoom out
Zoom in
Vorherige Seite
1/78
Nächste Seite
32
If you carry out a resistance measurement, make sure that the measuring points which you
contact with the measuring prods are free from dirt, oil, solderable lacquer or similar. An
incorrect measurement may result under such circumstances.
d) Diode test
Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
1. Turn the DMM on and select measuring range with the rotary switch (5).
2. Insert the red measuring lead into the socket (8) and the black measuring lead into the COM
socket (9).
3. Check the measuring leads for continuity by connecting both measuring prods to one another. After
that the value must be approximately 0 V. An acoustic signal can be heard.
4. Now connect the two measuring prods with the object to be measured (diode).
5. The display shows the continuity voltage in volt (V). Open-circuit voltage is about 2.6 V.
6. If “1” (towards the left side of the display) is shown, the diode is measured in reverse direction or
the diode is faulty (interruption). Perform a counter-pole measuring for control reasons. The red
measuring lead corresponds to the positive pole (anode), the black measuring lead to the negative
pole (cathode). A silicone diode has an on-state voltage of approx. 0.5 – 0.8 V. If the diode is place
in the correct direction, an acoustic signal can be heard.
7. After measuring, remove the measuring leads from the measuring object and turn the DMM off.
Turn the rotary switch (5) to the position “OFF” .
e) Continuity test
1. Turn the DMM on and select measuring range with the rotary switch (5).
2. Insert the red measuring lead into the socket (8) and the black measuring lead into the COM
socket (9).
3. Check the measuring leads for continuity by connecting both measuring prods to one another. After
that the value must be approximately 0 V. An acoustic signal can be heard.
4. Now connect the two measuring prods to the two contact points for checking continuity.
5. The display shows the continuity voltage in volt (V).
6. If “1” (towards the left side of the display) is shown, the two contact points are not in a closed circuit.
If the two end points are in a closed circuit, the resistant is less than 10 Ω, an acoustic signal can
be heard.
7. After measuring, remove the measuring leads from the measuring object and turn the DMM off.
Turn the rotary switch (5) to the position “OFF” .
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Voltcraft VC155 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info