Lubricating
system
ENGINE
Oil
quantity
model
2001
.
. .
.
.
. . . .
.
.
.
.
.
1,40
dm
3
(1
.2
quarts)
Oil
quantity
model
2002
. . . .
.
. . .
.
2
.75
dm
3
(2
.42
quarts)
Oil
quantity
model
2003
. . . . . .
.
. . .
.
. . .
.
. . . . .
. .
4,10
dm
3
(3 .6
quarts)
Oil
quality
according
to
the
API-system
CD
(DS)
Viscosity
. . . . .
.
. . .
.
.
.
.
. . . . . . .
.
.
. .
.
. .
.
15
W/40
Oil
pressure,
warm
engine,
idling
speed
. . . . . . .
.
. . .
.
. . .
.
0,8-1,5
kp/cm2
(11
.37-21
.33
lbft/in
2
)
Oil
pressure,
warm
engine,
full
rpm
. .
. . . . . . . . .
.
. . .
.
. . .
.
3,5-4,0
kp/cm
2
(49
.78-56
.89
lbft/in
2
)
Lubricating
oil
pump
Type
.
.
.
.
. .
.
. . . . .
.
. . . . . . . . . . .
. . . .
. . . . . . . . . . . . .
.
.
.
. . .
.
.
Gearwheel
pump
Gear
wheel
axial
clearance
. . . . . . . . . . . . . . . . . . . . . .
.
. . .
.
.
0,025-0,065 (0,00098-0,00256
in
.)
Spring
for
reduction
valve,
length
unloaded
. . . . . .
.
. . . . .
49
mm
(1,92913
in
.)
Loaded
with
35
Nm
(3,5
kp) (25
.8
ft
.lbs
.)
. . . . . . . . . . . . . . . .
40
mm
(1,57480
in
.)
Fuel
System
Opening
pressure
.
injectors
.
. . . . .
.
.
.
. . . . . . .
.
. . . . . . .
.
. .
.
180-190
kp/cm
2
(2560-2702
lbft/in
2
)
1)
Spray
angle
. . . . . .
. .
. . . .
.
__
. . .
. .
.
.
. . . .
.
. .
.
. . .
.
.
.
.
.
. . .
150
°
Injection
angle
2001
. . . . . .
.
. . . . . .
. .
. . . . .
22±1
°
B
.T
.D
.C
Injection
angle
2002,
2003
.
. . . . . . .
.
.
.
.
.
. . .
.
. . . . . . .
. .
. . .
20+1°C
B
.T
.D-C
.
Injection
angle
2003T
.
.
. . . . . . . . . . . . . . . . . . . . .
.
. .
.
. .
23±1°
B
.T .D
.C
.
Injection
quantity
. .
. . . . . . .
.
. . .
.
. . . .
25+1
.5
mm3/stroke
at
40±5°C
(104°F±10
.6°F)
and
at
25
r/s
(1500
rpm)
pump
revs
Governor
overrun
. .
. . . . . .
.
. . .
.
. . . . . . . . . . . . .
.
. . . . . . . . . .
54
r/s
(3250
rpm)
Feed
pump
Feed
pressure
42
r/s
(2500
rpm)
. . .
.
.
.
. . . . . .
.
. . . .
.
. .
.
. .
. . . .
0,65-0,85
kp/cm
2
(9
.20-12
.10
lbf/in
2
)
Electrical
system
Battery voltage
.
.
.
.
. .
.
.
. . . . . . . . . . .
.
. . . . .
.
. . . . . . . .
.
. . . . .
12V
Battery
capacity
. .
.
.
.
.
.
. . . . .
.
. . . . . . .
.
. . . . . . . . . . : . .
.
.
.
. . . . .
Max
.
70
Ah
Starter-motor
output
2001
. . . .
.
. . .
.
.
.
.
.
. . . . .
.
. . . . .
.
-
0
.8
kW
!1
.1
H
P)
Starter-motor
output
2002
and
2003
.
.
.
.
. . . . . . . . . . .
.
. . . . . . .
1
.4
kW
(1
.9
HP)
Alternator
output
:
Voltage/max
.
current
.
.
. . . . . . . . . .
.
.
.
. . . . . . . . . .
. . .
. . . . .
14W50
Amp
Output
. . . . . . .
.
. .
.
. . . . . . . . . . . . . .
.
.
.
. . . . . . . . . . .
. .
. . . . .
700
Watts
Electrolyte
spec
.
gravity
:
Fully
loaded
battery
. . . .
. .
.
.
.
.
.
1,275--1,285
To
be
charged
at
.
.
. . . . . . .
.
. .
.
. . . . .
.
.
.
. . . . . . . . .
. .
. . . . .
1,230
Thermostat
. . . . .
.
.
.
.
.
. . . . . . . . . . . .
.
.
.
. . . . .
.
. . . . .
. .
.
.
.
.
.
Wax
thermostat
Begins
to
open
at
.
.
.
.
. . . . . . . . . . . .
.
.
.
.
.
. . . . . . .
. .
.
.
.
.
. . .
60±2`C
(140±4°F)
Fully
open
at
. .
.
.
.
.
.
.
.
. . . . .
.
. . . . . . . .
.
.
.
. . . . . . . . . .
.
.
.
.
.
.
75'C
{165
°
F1
Cooling
system
With
fresh-water
cooling
(2002,
2003)
Starts
opening
at
.
.
.
.
.
.
.
.
.
.
. . .
.
.
.
.
.
. . . . .
.
.
.
. . . . .
.
.
.
. . . . . .
74±1°C
(164±2°F)
Fully
open
at
.
.
. . .
.
.
.
.
.
.
.
.
.
. . .
.
.
.
.
.
.
. .
.
.
.
.
. . . .
87°C
(189
°
F)
Fresh-water system,
volume
2002
.
.
.
.
.
. . . . .
.
.
. .
. .
.
.
.
. .
.
. . .
4
.0
dm
3
litre)
(0
.88
Imp
.
gals)
(1 .1
US
gals)
2003_____
5
.5
dm
3
(litre)
11
.2
Imp
.
gals)
(1
.45
US
gals)
WEAR
TOLERANCES
Cylinders
To
be
bored
at
0,25
mm
wear
(0,00984
in
.)
Crankshaft
Main-
and
big-end
journals
:
Permitted
out-of-round
.
. . .
.
. .
.
. . .
.
. . .
.
. . . .
.
. . . . . . . . . . .
0,06
mm
(0,00236
in-)
Permitted
taper
. .
. . .
. .
. . .
.
.
.
.
.
. . .
.
. . .
.
.
. . .
.
. . . . . . . . .
. .
0,05
mm
(0,00197
in
.)
Max
.
axial
clearance
on
crankshaft
.
. . .
.
. . . . . . . . . . . . . . . .
0,40
mm
(0,01575
in
.)
1)
2003T
=
204-212
kp/cm2
(2900--3015
lbf/in
2
)
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Volvo Penta 2003 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Volvo Penta 2003

Volvo Penta 2003 Bedienungsanleitung und Installationsanweisung - Englisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info