Keep a minimum distance of 10 m between any electrode of the energiser and other
grounding systems (e.g. protective grounding of a power distribution system or a
grounding of a telecommunication system).
Ensure that connection lines that are routed inside buildings are eectively insulated
from earthed, load-bearing parts of the building. To ensure this, use insulated high-
voltage cables.
Ensure that underground connection lines are routed through electrical conduits made
from insulating material or otherwise use insulated high-voltage cables.
Ensure that connection lines are not damaged by sinking animal hooves or tractor
wheels.
When installing the electric animal fence, do not use the electric conduit from any
external sources, third parties i.e. telecommunication companies or the main power
conduit entering the building.
The electric animal fence must be no less than 2.5 m away from earthed, metallic
objects (e.g. drinking troughs, water pipes). This is particularly important in areas
where people may be present.
Do not cross connection lines and electric animal fence wires over high-voltage or
communication lines.
Avoid crossings with high-voltage lines. If this cannot be avoided, the crossing must be
made below the power line at a 90° angle and as close as possible.
Do not power an electric animal fence with two separate electric fence energisers or
from the independent fence circuits of the same energiser.
Barbed wire or razor wire must not be electried with an energiser.
Non-electried barbed wire or razor wire may be used to support one or more
oset electried wires of an electric animal fence. The electried wires must be kept
at a vertical distance of at least 150 mm from the non-electried wires by means of
supports. Make sure that the non-electried wire is earthed at regular intervals.
There must be a minimum distance of 2.5 m between two separate electric animal
fences, which are powered by separate independently clocked electric fence energisers.
If there should be a physical barrier between the fences then only use electrically non-
conductive materials or an insulated metal barrier.
Ensure that all mains-operated auxiliary equipment connected to the electric animal
fence has the same degree of insulation as the energiser used.
Ensure that the auxiliary equipment is weatherproof. Outdoor use is only permitted if
it has been certied by the manufacturer and the equipment has a minimum degree
of protection of IPX4.
2.3 Safety during Operation
Lightning can cause res and lead to malfunctions on electric fences. Separating the
energiser from the fence and power source before a storm or possible lightning strike
can minimise the eects of lightning. Redirect the current of the lightning strike to the
ground before it damages the energiser by installing a lightning rod between the fence
and the energiser.
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Voss Impuls duo wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Voss Impuls duo

Voss Impuls duo Bedienungsanleitung - Englisch - 25 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info