Up to a static height of 10 m, the capacity pressure expansion vessel is dependent on the
water capacity of the system as follows:
Water content Vessel size
Litre Litre
up to 111 12
112 - 167 18
168 - 231 25
232 - 324 35
325 - 463 50
464 - 741 80
There should no manually operable shut off valves installed between the expansion vessel
and the stove.
A ventilation section at least 0.5 m above the highest circulation point in closed systems
with a diameter of at least 1 should be arranged and a ventilation valve provided at the
upper end.
In gravity systems the rise and fall of horizontal pipes should be at least 0.5 cm/m.
Radiators with more than 25 ribs or plate heat exchangers over 1.5 m long should be di-
agonally connected to the flow and return pipes.
Where there is a lower distribution ventilating valve it must be provided on each radiator.
The radiators should not be inclined towards the ventilation. As radiators are usually at the
same level on the floor where the stove is installed, these radiators should all be connected
to a circulating pump as matter of course.
If however a pure gravity plant has to be executed without pumps, then the centre of the
radiator should not be lower than the centre of the boiler.
In the simplest installation case, the circulation pump is connected to the mains by a switch
and runs continuously during the heating period, while the water capacity of the stove is
regulated by an integrated temperature controller.
The pumps can however also be controlled from a maximum-thermostat in the domestic
water boiler, to ensure a minimum temperature for the domestic hot water.
It is also possible to switch the circulating pumps through a room thermostat. In this case
however the gravity circulating domestic water boiler should not have a capacity of less
than 260 l, if there are no other radiators on gravity circulation are connected.
Independently of the control types described above, the heating circulation and/or boiler
loading pump should primarily be controlled through a thermostat with a fixed switch on
temperature of between 50 and 55 °C, situated immediately at the stove's return flow con-
nection following an adjustable bypass close to the stove between the flow and return
lines, to avoid a low temperature operation of the stove boiler.
In the installation unit which can be supplied as an accessory there is a thermal boiler
monitor integrated as a continuous regulating valve. The pump controls mentioned above
are then not needed.
50

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Wamsler K148F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info