extent, and then fully after a few seconds. In addition, if you intend
to put additional fuel into the fire, before the opening of the door
only there may be only ember bed in the burning space, i.e. no
flames may be visible.
13. In heating mode, the surfaces, inspection glasses and handles may
become very hot. Warn children of these threats, and keep them
away from the fireplace when heated.
14. Ensure that the ashtray should be fully inserted, and in particular
never remove hot ash from the fireplace (fire risk).
15. In transitional periods, chimney draught may drop, resulting in the
imperfect suction of the generated flue gases. In such cases, the
fireplace is to be filled with smaller quantities of fuel, preferably
wooden chips or wood wool, and it is to be commissioned under
control with the stabilization of the chimney draught. The fire grate
should always be kept clean.
16. After the heating season, it is recommended to have the equipment
inspected by an expert. It is also advisable to clean the routes of flue
gases and pipes.
17. Should repairs or reconditioning be needed, please, contact your
dealer in a timely manner with the accurate specification of the arti-
cle and serial number. Only original Wamsler parts may be used.
18. As the air needed for burning is drawn from the room where the
fireplace is located, ensure that sufficient air supply is received via
the gaps by the windows and external doors. Make sure that 4 m
3
of
air should be provided to each kW of rated performance. For this
fireplace, it means that the room has to be at least 32 m
in volume. If
the room is smaller, sufficient air supply can be secured by opening
air connections to other rooms with air openings (at least 150 cm
2
).
19. Ensure to keep proper lateral and rear distances from combustible
parts and materials. The associated values are specified in these
user instructions or the model plate.
20. The fireplace may not be modified.
21. The connection of the fireplace to the chimney is not permissible if
the effective height of the chimney is less than 4 m, or 5 m with mul-
tiple loading. To the chimney that the fireplace uses, a maximum of
two other fireplaces, ovens may be connected.
22. In the event of any chimney fire, immediately close all the openings
of the equipment, and call the fire service. Never try to extinguish
the fire with water. Thereafter, always have the chimney inspected
by an expert.