MILUX RF
General safety information
The instructions describ ed in this manu al m ust be obs erved. Fail ure to com ply with
theses instructions will result in mat erial dama ges, injury or fat al accidents.
This product must be used ex clusiv ely to regulate heating installations.
Other use is not c ompliant
Contents
1. Product characteri stics
2. Display
3. Keypad
4. First use
5. RF Configuration
6. Standby switch
7. Operating modes
7.1. TIME SETTING m enu
7.2. COMFORT Mode
7.3. REDUCED Mod e
7.4. AUTOMATIC Mod e
7.5. PROGRAM Men u
7.6. ANTIFREEZE Mode
8. Special functions
8.1. HOLIDAY functio n
8.2. Keypad lock
8.3. Cooling function
8.4. RESET function
9. Battery replacement
10. ITCS function (opti onal)
11. Technical characteristi cs
12. Problems and soluti ons
13. Recycling
14. Annexes
1. Product characteristics
W ireless comm unication b y radio si gnal with the r eceiver con nected to
the installation.
W eekly programm ation by 1 hour step
9 built-in programs
4 user program s
Program graphic displ ay
Room temperature and time dis play.
Comfort / Reduce d / Anti-free ze temperatures.
Temporary tempe rature override
Automatic or Manual operation
Holiday function
Keypad lock functi on (child safet y)
Battery operated > 2 years
Low batter y pictogram
Battery replaceme nt without loss of the program memor y except t he
hour
« O / I » switch f or standb y mode
Intelligent Temp erature Control S ystem func tion (optional): ITCS
2. Display
[1 ] : Operating m ode menu
[2 ] : Temporar y temperature ov erride
[3 ] : Heating in dicator
[4 ] : Room tempe rature or set t emperature
[5 ] : Cooling indi cator
[6 ] : if displayed , [4 ] indicates t he ambient temper ature
[7 ] : Holida y function activated
[8 ] : Current da y graphic progr am
[9 ] : Hour
[10 ] : Da y of the week (on ly available on weekl y version)
[11 ] : Low batteri es
3. Ke y pad
4. First use
Check that the batte ry protection is well removed.
Put the switch on « I » position (s ee chapter 6- stanby s witch))
Adjust the date and t he hour (see c hapter 7.1 T IME SETT ING menu)
Do the thermostat R F configuration with the receiver (Se e chapter 5. RF
configuration)
The thermostat is rea dy for operation. T he default oper ating mode is the
automatic m ode with t he factory prog ram “P1 ”, (see the detailed program
“P1 ” in the annexes ) .
You can custom ize your p rogram as you want. To do s o, refer to chapter 7.5
PROGRAM Men u.
5. RF configuration
Put the receiver(s) to c onfigurate in RF configu ration m ode (see
receiver’s leaflet).
On the thermos tat, select the Aut omatic mode . P ress 5 seconds
on (OK ) key. If you are in RF configuration mode, the message «
» must appear. The thermostat sends it s
configuration ad ress by radio sign al .
Check on the receiver tha t the configuration is well done (see
receiver’s leaflet).
Verify the radio oper ating dist ance. Put the th ermostat in the wanted
room to regulate t he temperature. Let it in R F configuration m ode :
“ ” is displ ayed. Close the doors and come back to
the receiver. Check the green LED on the receive r:
o If t he LED blinks regula rly several tim es per second, your
installation is func tional.
o If th e LED blinks irregularly and only one time, you are at
the range limit.
o If the LED doesn’t blink, you are out of range lim it. Bri ng
imperatively your thermostat close r to the receive r.
Press (OK ) k ey on your th ermostat to exit the RF config uration mo de.
Now, you thermost at operates with the receiver.
6. Standby switch
This switch is locat ed under the product as sho wn below :
To put the product in st andby, put the switch on « O » positio n. The sc reen
switches off t o reduce battery co nsumption. T he k eys (+ ), (- ), (◄) and (►) b ecome
inactive. A press on (OK ) k ey all ows displa ying briefly the ambient temp erature
and the hour, tog ether with the pictogram:
To activate the pro duct, put the s witch on « I » positio n. D uring 3 se conds, the
software version will be displayed. Then, the thermost at c omes back in the
selected operatin g mode befor e the standb y.
WARNING: In t his standby mode, your installation c an freeze.
7. Operating modes
Use the navigati on keys (◄) o r (►) to change th e operating mo de.
7.1. TIME SETT ING menu :
Press (OK ) t o enter in the men u. The m inute display is flas hing.
Set minute value with (+ ) and (- ) ke ys
Press (OK ) k ey to validat e.
Set hour value with (+ ) and (- ) k eys
Press (OK ) k ey to validate.
( (►) key allows to return to the min ute setting)
W eekly version
Set day value with (+ ) and (- ) keys
(1=monday, 2= tuesda y, …)
Press (OK ) k ey to validate
7.2. COMFORT Mode :
In this mode, th ermostat applies co mfort se tpoint temperat ure indefinitely. B y
pressing (+ ) or (- ) keys , setpoint tempe rature flashes and can be adju sted:
The ambient temp erature is displayed after f ew seconds:
A press on (OK ) key allows t he displayi ng of comfort setpoi nt temperatur e.
To apply tempo rarily comfort mo de, use the s pecial function « HO LIDAY ».
7.3. REDUCED Mode :
In this mode, the th ermostat applies reduced s etpoint temper ature indefinitel y
By p ressing (+ ) o r (- ) k eys, setpoint te mperature flashes and can be adjusted lik e
the COMFORT temperat ure. The a mbient temperature is displa yed after f ew
seconds. A press on (OK ) k eys al lows th e displ aying of reduce d setpoin t
temperature.
To apply temporaril y reduced m ode, use the speci al function « H OLIDAY ».
7.4. A UTOM A TIC Mode :
The thermostat follows the chosen program (see chapter 7.5 for the progra m
selection / edition) with respect t o curre nt hour.
By pressing (+ ) and (- ), an o verriden temperatu re can be adjuste d until the next
program step:
The pictogram is displa yed.
At the n ext program change , the pictogram will disapp ear and the program will
carry on.
7.5. PROGRA M Menu:
Press (+) or (-) k eys to choose a program number:
= Comfort setpoint temperature set i n the CO MFORT mode
= Reduced setpoint temperature s et in the REDU CED mod e
If you s elect a built-in program « P1 to P9 », press ( OK ) ke y to appl y this
program in the aut omatic mode .
A light weekl y programs descriptio n is given b elow:
Morning, Evening & W eek -end
Morning, Midi, Eve ning & W eek-end
Morning, Evening (bathroom)
Morning, Afternoon & W eek-end
8h - 19h, Satu rday (Shop)
W eek-end (Secondary House)
A detailed programs description is gi ven in annexes.
If you s elect a user program « U1 à U4 », p ress ( OK ) k ey to enter in edition
mode :
W ith navigation keys ( ◄) a nd ( ►), mo ve the blinking cursor on the hour of the day
that you want to m odify.
W hen the day seems to be cor rectly edited, press (OK ) key.
Daily version: the day’s pr ogram is val idated for ever y day of the week .
Weekly versi on: you switch to the next day edition. By validating t he da y 7, you
validate the progr am edition. T his program will b e follo wed b y your therm ostat i n
automatic mode (see chapter 7 .4).
7.6. A NTIFREEZE Mode :
In this mode, th e thermostat a pplies antifree ze setpoi nt temperatur e indefinitely. B y
pressing (+ ) or (- ) k eys, s etpoint t emperature flashes and c an b e adj usted lik e the
COMFORT temperature. The ambi ent temperature is displayed aft er f ew
seconds. A p ress on (OK ) k eys allows the displa ying o f the a ntifreeze setpoint
temperature.
To apply temporaril y the antif reeze mode, use the special functi on « HOL IDAY ».