805498
1
Zoom out
Zoom in
Vorherige Seite
1/3
Nächste Seite
USER GUIDE
GB
HUMIDITY THERMOSTAT & ZONES PROGRAMMER
oWeekly and 12 zones programmer.
oPermanent memory storage
oRegulation by internal or external probe in option.
oHeating, Cooling and humidity control.
TECHNICAL CHARACTERISTICS
Measuring accuracy 0.1°C
Operating temperature 0°C - 50°C
Ambient temperature range 5° C – 37° C in steps of 0.5° C
Regulation characteristics Integral proportional band (PWM) or Static differential.
Electrical Protection Class II - IP30
Feeding and autonomy 3 batteries AA LR06 1.5 V / > 2 years (alkaline batteries)
Radio frequency and
certifications
433,92MHz, < 10mW
CE. EN 300220-1, EN 301489-1
External probe in option CTN 10K 3M
Program version To display the software version press the during 3sec in anti freeze
mode . “Crf _.__”
DISPLA
Y
1: Function mode.
2: Heating mode indicator.
3: Cooling mode indicator.
4: Ambient temperature indicator.
5: Ambient temperature if “4” lit up, current zone or
temperature required.
6: Weekly program / Radio frame.
7: Humidity level or time.
8: Current day of the week.
9: Low batteries.
10: Holiday mode.
OPERATING MODE DESCRIPTION
Use and keys to change operating mode.
Humidity Mode:
Use and to set the maximum humidity value (in relative humidity percent) of your room.
The humidity drier output will be switch on when the current humidity is above this value.
This output is controlled only in cooling mode “Mod COOL ” or ‘Mod AUTO” in cooling.
PPL IMP 1305 A
INSTALLER’S PARAMETERS
To access to the installation parameters menu, press during 10 s.
Use and keys to show the parameter to adjust.
Press to toggle the parameter setting or edit the value. If the value starts to blink you can use and
keys to adjust this value. Press and keys at the same time to reset this value to the factory default value.
Once you have adjusted the value press to validate this parameter value.
When you have finished, go to « CrF Init » parameter and press to go back to the main menu.
Installation parameters:
name Description Default setting Other possibility
CrF Init Use this parameter to configure the thermostat with the receiver.
J0 °C or °F temperature display selection °C °F
J1 12h or 24h time display 24h 12h
CH Numbers of zones installed on your installation 12 Adjustable « 01 » to « 12 »
H.C
Type of installation:
Menu: The cold warm change is manually
managed by the end user. (On the thermostat)
Auto: The cold warm change is managed by the
automatic reversible Heat pump. (Special input on
the RF Receiver)
Menu Auto
J2
Select Hot or CoLd to adjust :
if lit up => adjust the heater parameters.
if lit up => adjust the cooler parameters.
Hot CoLd
J5
Anti-lock-braking function of the pump
When the pump hasn’t worked on a particular day,
start it up for one minute each day.
(adjustable in & in Menu position)
Yes no
J6 Air or Floor temperature regulation selection.
(if no Floor sensor, regulation will use Air sensor) Air FLor
J7
Selection of regulation type
(adjustable in & in Menu position)
Bp
(PWM)
« hyst »
static differential of 0.5°C
Cy
Selection of the proportional band duration in
minutes
(adjustable in & in Menu position)
15 =>
Slow system
adapted to each
heating type
30 =>
adapted to Heat
pump control
Heating application :
Burner oil « 20 »
Burner gas « 10 »
Actuator « 10 »
Heat pump « 20»
Cooling application :
Heat pump/ Air conditioning « 30»
Ventilate convector « 10 »
On
Minimal starting time in minutes
(adjustable in & in Menu position)
2 =>
4 =>
Adjustable, 0 to ½ Cy
OF
Minimal resting time between 2 heating cycles in
minutes
(adjustable in & in Menu position)
3 =>
4 =>
Adjustable, 0 to ½ Cy
bP
Value of the proportional band (PWM)
(adjustable in & in Menu position)
2.0°C =>
4.0°C =>
Adjustable 1°C to 6°C
A well insulated house 1.5°C
In case of your house has not a
good insulation increase this value.
Ao Air sensor offset adjustment.
Display measured Air sensor value. No offset Adjustable +/ 12°C
Fo Floor sensor offset adjustment.
Display measured Floor sensor value. No offset Adjustable +/ 12°C
FL
Floor temperature LOW limitation,
Effective only if floor sensor present.
(adjustable in & in Menu position)
18°C =>
18°C =>
Adjustable 5,0 °C to FH
FH
Floor temperature HIGH limitation,
Effective only if floor sensor present.
(adjustable in & in Menu position)
28°C =>
37°C =>
Adjustable FL to 37°C
GAP Value of the dead zones (only for “Mod Auto”) 4,0°C Adjustable 0,2°C to 25 °C
dLY Time delay between the Heat and Cold
commutation in minutes (only for “Mod Auto”) 60 Adjustable 1 to 240 min
CLr Press during 5sec to reset your thermostat, all parameter will reload with default values.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Watts Milux Hygrostat wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info