If the output is “not used” there is the possibility to use the
output as a booster pump of the main pump P1 with System 1.
This function is useful when utilizing a “drain back system” to
enable the primary pump P1 to initiate the circulation of the
heat transfer fluid.
In this instance pump P2 is normally installed in series with the
main pump P1.
- You could choose the duration for the running time of P2 with
(+) or (-). (Adjustable 1 to 10 minutes)
Booster function explanation:
Exemple:
2.4.3 Pump P3
P3 is a supplementary output which can be used for an
additional extra function and is generally used in combination
with the solar system or totally independent. There will be a
choice between the different functions depending upon the
selected system configuration selected.
2.4.3.1 Thermostat Heating Function
With an additional sensor (T3) this function is used for
secondary heat source pump (P3) control.
Suggestions:
- Pump controls for Fuel or Gas burner…
- Immersion Electrical Heater inside the solar tank.
Important: In this instance an external power relay must be
connected for the switching of the output load!
Example:
All adjustable settings available for this function are accessible
in the Settings menu; see section “Settings” chapter 2 for a
further explanation of the functions.
2.4.3.2 Thermostat Cooling Function
With an additional sensor (T3) this function is used for
cooling of the solar tank with an external heat sink
Suggestions:
Charging a swimming pool.
Example:
All adjustable settings available for this function are accessible
in the Settings menu; see section “Settings” chapter 2 for a
further explanation of the functions.
2.4.3.3 Diffcontrol Function
With additional sensors (Tcold=T3, Twarm=T4) this function
is used for secondary heat source pump control or charging
a tank.
The loading of the Tcold=T3 is activated if the temperature
difference “dt” between the Twarm=T4 and the Tcold=T3 is
sufficient.
Example 1:
 Pump 2 --- -
P2 Booster
Boost Duration 2min
Tank1
T2 C)
dTMin
dTMax
P1
Collector
T1 C)
Maxtemp
Tank1
dTMax
dT = T1
T2
100%
0%
dTMax
Boost time
P2
T1
P1
T2
Extra Function to control a
second pump in serie with P1
to help the liquid circulation
startupthe pump coupled with
an external burner.
P2
Heat Source
T1
P3
P1
T3
T2
Extra Function to control
the pump coupled with
an external burner.
Heat
sink
T1
P
3
P
1
T
3
T2
Extra Function used to control the pump to
warm up another tank or basin
P3
P1
T2
Extra Function used to control
the pump (P3) to warm up
"Tcold=T3", if the temperature
difference (dt) to "Twarm=T4"
is sufficient.
T1
TC = T3
TW = T4
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Watts Solar Controller LCD PLUS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info