USER GUIDE
GB
RF basic thermostat WFHTRF 010 (20433)
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
- Radio frequency RF thermostat (433.92 Mhz) specially designed for water floor
heating. (Personal code on each product)
- Equipped with a LCD display to select comfort (
), Off or night reduction ( )
mode.
- Setting and room temperature displayed.
- To be used only with ours receivers.
PPL IMP 1017A
Measured temperature precision 0.1°C (or 0.2°F)
Operating temperature 0°C - 50°C (or 32°F – 122°F)
Setting temperature range 5°C - 37°C by 0.5°C step (or 41°F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation (adjustable see installation
menu) Cycle: 15 minutes or Static differential 0.3°K
Anti-short cycle: 3min in OFF, 2min in ON.
Electrical Protection Class II - IP30
Power Supply
Battery operated life
2 x 3V (CR2430)
~ 2 years
Radio frequency 433.92 MHz, <10mW.
certifications
CE. EN 300220-1, EN 301489-1
(Radio frequency certifications)
Soft version Displayed when the thermostat is turn Off
RADIO CONFIGURATION MODE
To assign (*) the RF thermostat with the receiver you must put the receiver in
“RF init” mode (please refer to the receiver leaflet).
After you have just Press
key during 5 sec, when the display( rF “”)
The thermostat sends its configuration address by radio signal.
When the receiver is configured, Press
key to return to user menu.
* (In this mode the thermostat should be near the receiver)
COMFORT operating mode:
Force comfort temperature operation indefinitely.
By pressing
&
keys the comfort temperature starts to blink and can be adjusted.
The measured temperature
reappears after a few seconds.
OFF mode:
Use this mode if your Heating installation needs to be turned OFF.
The display is blank.
(Careful in this mode your installation can freeze)
Parameters are saved.
REDUCED operating mode:
Force reduced temperature operation indefinitely.
By pressing
&
keys the comfort temperature starts to blink and can be adjusted.
The measured temperature
reappears after a few seconds.
1: Operating mode menu
2: Heater indication
3: Cooler indication
4: Batteries weak
5: If lit-up 6 displays the measured temperature
6: Measured temperature or set temperature
7: Moving bars when transmitting a radio signal
Or Title for installation Parameters (rF, J0,CLr…)
DISPLA
Y
Press the key during 5 seconds, Then use or keys to select the installation parameter to be adjusted.
Press to toggle the parameter setting or edit the value. If the value starts to blink you can use
&
keys to
adjust this value. Press
& keys at the same time to reset this value to the factory default value. Once you have
adjusted the value press
to validate this parameter value. When you have finished, use &
keys to go to
‘rF’ display and then press key to exit installation parameter menu.
rF : Radio configuration mode (see section). Press to return to normal operation modes.
J0 : °C
/ °F temperature display selection
J1 : “Hot” / “Cold” regulation mode. Select Hot for a Heater system, select Cold for a Cooling system
Cy : Proportional Integral regulation time cycle value in minutes (default: 15 minutes cycle)
bp : Proportional Integral regulation band amplitude value in degrees °C/°F (default: 2.0°C
/3.6°F)
J5 : Select “PMP” to perform an 1 minute exercise everyday (if installation inactive during a day)
J6 : Air
or Floor temperature regulation selection. (if no Floor sensor, regulation will use Air sensor)
J7 : “rEG” (Proportional Integral) or “HYs” (0.3°K Hysteresis) regulation type selection
Cp : compensation value in °C/°F (default: 2.0°C/3.6°F) this parameter must be adjusted by a professional.
Ao : Air sensor offset adjustment (default: no offset). Display measured Air sensor value
Fo : Floor sensor offset adjustment (default: no offset). Display measured Floor sensor value
FL : Floor temperature LOW limitation (default: 5°C
/41°F), effective only if floor sensor present
FH : Floor temperature HIGH limitation (default: 28°C
/82°F) , effective only if floor sensor present
CLr : Press key during 5s to reset all the WFHT LCD parameters to factory defaults
* (Default parameters are underlined.)
INSTALLATION PARAMETERS MENUS
Optional external sensor 10K
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Watts WFHTRF 010 -20433 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Watts WFHTRF 010 -20433

Watts WFHTRF 010 -20433 Bedienungsanleitung - Deutsch - 4 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch - 4 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch - 4 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch, Spanisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info