GB
RF basic thermostat WFHTRF 010 (20433)
TECHNICAL CHARACTERISTICS
PPLIMW01332Ca
Measured temperature precision
0.1°C (or 0.2°F)
Operating temperature
0°C - 50°C (or 32°F 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step (or 41°F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation
(adjustable see installation menu) Cycle
Anti-short cycle: 3min in OFF, 2min in ON.
Electrical Protection
Class II - IP30
Power Supply
Battery operated life
2 x 1,5V (AAA) ALKALINE type
~ 2 years
Radio frequency
868 MHz, <10mW.
CE Directives
Your product has been designed in
conformity with the European Directives.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
RADIO CONFIGURATION MODE
To assign (*) the RF thermostat with the receiver you must put the receiver in “RF init” mode
(please refer to the receiver leaflet).
After you have just Press key during 5 sec, when the display (rF “”). The thermostat sends its configu-
ration address by radio signal.
When the receiver is configured, Press key to return to user menu.
* (In this mode the thermostat should be near the receiver)
DISPLAY
INSTALLATION PARAMETERS MENUS
Optional external
sensor 10K at 25°C
MODE DESCRIPTION
Use key to change the mode in the Operating mode menu
COMFORT operating mode:
Force comfort temperature operation indefinitely. By pressing keys or the comfort temperature starts to
blink and can be adjusted. The measured temperature reappears after a few seconds.
REDUCED operating mode:
Force reduced temperature operation indefinitely. By pressing or keys the comfort temperature starts to
blink and can be adjusted. The measured temperature reappears after a few seconds.
Press the key during 5 seconds, then use or keys to select the installation parameter to be adjusted.
Press to toggle the parameter setting or edit the value.
If the value starts to blink you can use or keys to adjust this value.
Press and keys at the same time to reset this value to the factory default value. Once you have adjusted the
value press to validate this parameter value.
8
7
6
1
2
3
4
5
The manufacturer herewith
declares that the device
WFHT THER LCD RF 868
complies with the basic
requirements and all other
relevant regulations of the
1999/5/CE directive.
This thermostat can be
used in all EU and
EFTA countries.
ON
OFF
Switch on and switch
off the thermostat
Use the switch on the right side of the thermostat to power on or power off the heating.
Be careful! In this mode, your installation can freeze.
The setting temperatures are kept in memory indefinitely.
START UP
Default value & other possibilities
rF: Radio configuration mode (see the corresponding section).
Press (OK) on this parameter to exit the parameters menu end come back to the main display.
JO: Type of degrees displayed
°C Celsius
°F Fahrenheit
J1: Operating mode:
Hot for heating application
CLd for cooling application
J5: Anti-lock-braking function of the pump when the pump hasn’t worked on a particular day, start it up for one minute each day:
Pmp Function activated
no Function deactivated
J6: Selection of the sensor used for the regulation:
Air: Room sensor only or room sensor with floor limitation if the external sensor is connected.
Flr: External sensor only without limitations.
A0: Calibration of the internal sensor
(The calibration must be done after 12Hours working with the same setting temperature)
- To check the temperature in the room, put a thermometer at 1.5m distance to the floor in the concerned room and wait 1
hour to be sure that the thermometer shows the correct temperature. Then you can enter the value saw on the thermome-
ter with (-◄) or (►+) keys.
F0: Calibration of the external sensor.
The calibration must be done same as described above if the external sensor is connected and used like an external ambi-
ance sensor.
If the external sensor is used as floor sensor, the thermometer should be put on the floor.
FL: Lower limitation of the floor temperature. Only effective if the external sensor is connected and selected:
18°C Adjustable From 5°C to „FH
FH: Upper limitation of the floor temperature. Only effective if the external sensor is connected and selected:
35°C Adjustable From „Fl“ to 37°C
J7: Selection of regulation type:
rEg: Proportional band (PWM)
hys: Static differential of 0.3°K
CY: Proportional Integral regulation time cycle
value in minutes:
15 slow systems adapted to the regulation of actuators.
On: Anti short cycle time ON:
2mn : Minimum time ON
Of: Anti short cycle time OFF:
2mn : Minimum time Off
Bp: Value of the proportional band in °C:
2.0 °C Adjustable 1°C to + 7°C
Increase the value if the temperature in the room is unstable.
Cp: Value of the compensation in °C:
2.0°C Adjustable 1°C to 8°C
* This value must be adjusted by a specialist.
Clr: All parameters are reloaded with default setting values.
End : Exit.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Watts WFHTRF 010 -20433 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Watts WFHTRF 010 -20433

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch - 4 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch - 2 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Englisch - 18 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Holländisch - 2 seiten

Watts WFHTRF 010 -20433 Bedienungsanleitung - Spanisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info