Operating Instructions Dual Top Evo 6
12
4.3 Frost
There are several features that protect the water supply system against frost.
Drain water contents manually when there is risk of frost and when storing the
vehicle for a longer period.
See paragraph 4.3.1: "Draining the boiler manually".
The boiler is drained automatically in case you forgot to drain manually.
See paragraph 4.3.2: "Draining the boiler automatically".
In case you don’t want to drain the water supply system and you don’t heat the
interior of the vehicle, you can select the frost protection mode.
See paragraph 4.3.3: "Frost protection mode".
4.3.1 Draining the boiler manually
Drain water contents manually when there is risk of frost and when storing the vehicle
for a longer period.
1 Interrupt power for vehicle system water pump (main switch or pump switch,
depending on instructions of the vehicle manufacturer).
2 Open hot water taps in kitchen, bathroom, shower, etc. (set pre-selecting mixing
taps or single-lever valves to "hot").
3 The electrical safety/drain valve is opened by turning and holding the mode
selector knob (A) against the spring force in the position drain boiler (6) for at
least 5 seconds.
Then, release the knob.
The electrical safety/drainage valve will open for approx. 90 minutes.
During drainage, all green icons on the control panel, as well as the red indicator
on the mode selector knob (A), are blinking.
The boiler content is now discharged to the outside through the electrical safety/
drainage valve.
Place a container beneath the outlet to check whether the water in the boiler has
completely drained away (approx. 10 litres!).
NOTE
Any kind of water from the vehicle has to be discharged at a proper disposal facility.
NOTE
Drainage can be stopped by again moving mode selector knob (A) to drainage mode
(6) for at least 5 seconds and then releasing the knob.
NOTE
Avoid the formation of micro-organisms in the lines and in the boiler during storage and
make sure that the water supply system is completely drained. To do this, open all water
valves, connect an air pressure of approx. 2 bar to the hot water line and leave it
connected until the residual water is completely drained off.
4.3.2 Draining the boiler automatically
The electrical safety/drainage valve is opened electrically.
If the water temperature at the electrical safety/drainage valve is less than 6 °C, the
boiler water contents may discharge automatically.
This function is active when:
the appliance is switched "OFF";
in winter mode (heating without hot water production) during a period when there
is no heating action in the heater (e.g.: selected interior temperature is reached, low
outside temperature);
if battery power is too low;
there is a failure!
NOTE
Note that it only works when a 12 V power supply is available!
During drainage, all green icons on the control panel, as well as the red indicator on the
mode selector knob (A), are blinking.
After approx. 90 min, the electrical safety/drainage valve will be closed again.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Webasto Dual Top Evo 6 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Webasto Dual Top Evo 6

Webasto Dual Top Evo 6 Bedienungsanleitung - Deutsch - 25 seiten

Webasto Dual Top Evo 6 Bedienungsanleitung - Holländisch - 25 seiten

Webasto Dual Top Evo 6 Bedienungsanleitung - Französisch - 25 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info