Webasto Charging the A/C system | 6
6244481A_ES_OI_II_Quebec-Montreal_R1234yf 5 / 8
1
2
3
5
4
Fig.4: Refrigerant bleeding
Vehicle interior Bleeding in case of refri-
gerant leakage
Vehicle floor Enclosure in case of off-
floor installation
Vehicle exterior
üAvoid making connections to the refrigerant circuit inside
the passenger compartment of the vehicle. In case the con-
nections are inside the vehicle, the joint must be segreg-
ated from the interior using seals and/or sealant and open
to vent outside the vehicle any eventual refrigerant leak.
üThe venting opening must be kept away from hot surfaces
and / or ignition sources.
üAvoid locating refrigerant connections e.g. hoses to fittings,
fittings to components (valves, filters, pressure switches,
safety valves, etc.) and charge ports in areas close to hot
surfaces (e.g. exhaust pipe, catalyst, engine block, etc…) or
elements likely to generate sparks or electric arcs.
üAvoid the installation of refrigerant solenoid valves inside
the vehicle.
uIn case not already installed: always install over-pressure
safety valves venting in area far from hot surfaces, power
electric lines and any other ignition source.
5.4 Installation
1
1
Fig.5: Mechanical installation
The unit comes prepared with 2 M6 rivet-nuts (1) on each side.
uSelect a suitable location for the unit.
uDesign brackets that firmly locate and hold the unit to the
vehicle interior.
The brackets should ensure stiffness and avoid vibrations
and potential cracks.
uMount the brackets on the unit with M6 bolts. Nominal
torque: 5Nm.
üMake sure you can work safely on the vehicle’s refrigera-
tion system.
uConnect the expansion valve to the vehicle’s refrigeration
circuit.
üFor a HVAC unit: Make sure you can work safely on the
vehicle’s cooling system.
uFor a HVAC unit: Connect the heater to the vehicle’s cooling
circuit.
5.5 Electrical connections
Fig.6: Electrical connections
1 + (red) 3 Compressor (yellow/green)
2 Gnd / - (black)
uMake the electrical connections according Fig. 6. See
„chapter9 for power and fuse requirements.
Avoid fitting relays, fuses and switches close to refrigerant
connections.
uInstall the control knobs/switches in a convenient location.
6 Charging the A/C
system
DANGER
Danger of fire
Carry out refrigerant charging operations in ventilated
areas, away from open flames, hot surfaces and any
other ignition sources.
Take into account these measures and all those aimed
at reducing the risk of ignition of the refrigerant in case
of a leakage.
Refer to SAE J 2845.
NOTE
Only use recovery/recycling/recharging equipment for
flammable refrigerants compliant to SAEJ2843.
uPerform a high pressure leak test with nitrogen. Accurately
solve any eventual leak to assure circuit tightness.
uPerform an evacuation test.
If present, activate the solenoid valves during the leak-test, va-
cuum and charge procedure to ensure the correct pressurization
of the entire system.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Webasto Quebec wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Webasto Quebec

Webasto Quebec Bedienungsanleitung - Deutsch - 8 seiten

Webasto Quebec Bedienungsanleitung - Französisch - 9 seiten

Webasto Quebec Bedienungsanleitung - Italienisch - 8 seiten

Webasto Quebec Bedienungsanleitung - Spanisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info