Exceeding the zero limits : As soon as a zero setting should exceed the limits, the zero setting is not
executed. In the data string, in digit 12, an error message appears : > or = ,
as well as on the internal display in the last two characters : Z > or Z = .
The previous zero value is maintained and may be requested for with
command : ? Z .
Delete zero memory : Both the zero memories of the zero track en initial zero setting are deleted
by setting both switch 4 and 5 off.
The zero memories are not deleted by switching off the 348.
4.3 ADJUSTING : DEAD LOAD COMPENSATION SWITCH 6 - 16
System : Dead load compensations used for suppressing permanent loads on a
weighing scale. F.e. a weigh hopper, platform, conveyor etc.
Here the dilswitches 6 up to 16 are used as hardware memory. The setting of
these switches is continuously transferred to a digital memory and is
subtracted from the actual A/D conversion value.
At any moment the setting of the switches may be changed, the weight reading
is adapted immediately.
Range : The 11 dilswitches have a total range of 1 mV/V, that is 50 % of the capacity of
2 mV/V loadcells. If this proves to be not enough a higher capacity of loadcells
should be applied.
Accuracy : The first switch at the left: switch 6, has the highest value: 50% of the range,
the next has 25% and so on until switch 16 with 0.05% effect, which is 0.1%
of the weighing capacity. These lasting 0.1% is set zero with switch 5 . See 4.2.
Procedure : Start with all the switches down (off), 4 and 5 included. Set switch 6 “on” and
check the effect on the internal display. If the weight value still is positive leave
the switch “on”. If the value is negative set the switch back “off”.
Proceed with switch 7 a.s.o. until switch 16. Finally switch 5 is set “on”
resulting in an exact zero reading.
Attention
: during this procedure all the span switches 17 t/m 32 should be “on”,
the division selector switches preferably at x 1: switches 53 up to 56 op 1 0 0 1
(on -off - off - on). Not all the overload switches 38 up to 48 should be “off” ,
preferably all “on” .
No interference with : Setting or changing the dead load settings and the digital zero memories
span adjustment does not effect in any way the span adjustment.
4.4 ADJUSTING : SPAN SWITCH 17 - 32
Weight adjustment : Using switch 17 up to 32 the scale may be adjusted, based upon an accurate
weight mass placed upon the scale, preferably 100% of the weighing capacity.
These switches determine the number of scale divisions that are applied on the
selected input sensitivity range. See 4.1
F.e. at an selected input range of 1 mV/V, the input signal of 1 mV/V is
divided into 15,000 divisions if all the switches are “on”. Setting back the
switches one by one will reduce this number, finally to 0 divisions.
At any moment the setting of the switches may be changed, the weight reading
is adapted immediately.
Manual 348-2 V 3.1 Page 14 01-06-2007
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Weightec 348 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Weightec 348

Weightec 348 Bedienungsanleitung - Holländisch - 49 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info