515832
15
Zoom out
Zoom in
Vorherige Seite
1/18
Nächste Seite
36
How to Purge Air Tubes
Thermal Insulation Piping:
Place the drain hose under the piping.
Insulating material: polythene foam over 6 mm in thickness.
NOTE: Drain hose is prepared by user.
Drain pipe should point downward for easy drain flow.
Do not twist the drain pipe, leave it sticking out or waving around, and do
not immerse the end in water. If an extension drain hose is connected to
the drain pipe, make sure it is thermally insulated when passing it through
the indoor unit.
When the piping is directed to the right, piping, power cord and drain pipe
should be thermally insulated and fixed at the rear of the unit with a piping
fixer.
1. Insert the pipe fixer into the slot.
2. Press to hook the pipe fixer onto the base.
Piping Connection:
Connect the indoor unit pipes using two wrenches. Pay special attention
to the torque allowed as shown below to prevent the pipes, connectors
and flare nuts from being deformed and damaged.
At first finger-tighten them, then use the wrenches.
For T3 climate kind models, 18 K and 24 K Liquid Side is (ø 6 or ¼ inch) and gas
side is (Ø 16 or 5/8inc).
Model Pipe size Torque
Nut
width
Min.
thickness
7-9-12 K Liquid Side (ø 6 or ¼ inch) 1.8 Kg.m 17 mm 0.6 mm
18,24 K Liquid Side (ø 10 or 3/8 inch) 3.5 Kg.m 22 mm 0.6 mm
7,9 K Gas Side (ø 10 or 3/8 inch) 3.5 Kg.m 22 mm 0.6 mm
12 K Gas Side (ø 12 or ½ inch) 5.5 Kg.m 24 mm 0.6 mm
18,24 K Gas Side (ø 16 or 5/8 inch) 7.5 Kg.m 27 mm 0.6 mm
Base
Piping fixer
Large pipe
Power
connecting cord
Power
connecting
cord 1 (for
heat-pump)
Drain hose
(prepared by user)
Small pipe
Thermally insulated
tube
Base
Piping fixer
Insert here
Large
pipe
Drain
hose
Small
pipe
Hook here
Defrost cable
(for heat-pump)
Unscrew and remove caps from 2 and 3-way valves.
Unscrew and remove cap from service valve.
Connect vacuum pump flexible hose to the service valve.
Start the vacuum pump for 10-15 minutes until it reaches an absolute vacuum of 10 mm Hg.
With the vacuum pump still running close the low pressure knob on the vacuum pump manifold. Then stop the vacuum pump.
Open the 2-way valve ¼ turn, then close it after 10 seconds. Check tightness of all joints using liquid soap or an
electronic leak detector.
Turn the 2 and 3-way valves stem. Disconnect the vacuum pump flexible hose.
Replace and tighten all valve caps.
NOTES:
Please read this manual before installing and using the appliance.
Do not let air enter the refrigerating system or discharge refrigerant when moving the air conditioner.
Test run the air conditioner after finishing installation, and record details of operation.
Type of fuse used on indoor unit control is 50 T, with rating 2.5 A,T,250 V.
The fuse for the whole unit is to be provided by the user according to the current at maximum power input or use
another over-current protective device instead.
The power connection for the air conditioner has to be made at the main power distribution which has to be of a low
impedance. In order to ensure the suitability of the equipment for connection, the user should consult the supply authority, if
necessary, to check that the service current capacity at the interface point is sufficient for the equipment. Refer to the rating
plate of the equipment for power consumption details. If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or similarly qualified person in order to avoid a hazard. When charging refrigerant into the system, make
sure to charge in liquid state, if the refrigerant of the appliance is R407C or R410a. Otherwise, the chemical composition of
the refrigerant inside the system may change and thus affect performance of the air conditioner. According to the character
of refrigerant (R410a), the pressure of the tube is very high, so ben sure to be careful when you install and repair the appliance.
Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect it if necessary.
If this is not possible, connect the appliance to a double-pole switching device with contact distance of at least 3 mm
placed in a position accessible even after installation.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Whirlpool AMD 002 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Whirlpool AMD 002

Whirlpool AMD 002 Bedienungsanleitung - Deutsch - 18 seiten

Whirlpool AMD 002 Bedienungsanleitung - Holländisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info